Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May;43(3):517-524.
doi: 10.1111/opo.13119. Epub 2023 Mar 7.

Development of smart spectacles to monitor and modify myopia-related health behaviour in children

Affiliations

Development of smart spectacles to monitor and modify myopia-related health behaviour in children

Dharani Ramamurthy et al. Ophthalmic Physiol Opt. 2023 May.

Abstract

Purpose: To develop a wearable, spectacle-mounted, sensor-based device to monitor and modify myopia risk factors in children, namely near-working distance, light levels and spectral composition.

Methods: A wearable, spectacle-mounted device has been developed, which consists of inbuilt sensors, namely: (i) light sensor to detect ambient light intensity; (ii) proximity sensor to measure near-work distance; (iii) microspectrograph to measure spectral power for six visible channels, namely red, green, blue, yellow, orange and violet and (iv) a global positioning system tracker to track the location and the device. The sensors were programmed by Arduino Nano, and the circuit was fixed onto a printed circuit board fitted onto a spectacle frame for pilot testing. Laboratory testing of the prototype was performed using a mannequin. An alert will be set when exceeding the predetermined threshold to help control myopia risk factors.

Results: The indoor and outdoor light levels measured using the prototype were less than and greater than 1000 lux, respectively. The actual target distance and the corresponding distance measured by the prototype were highly correlated (R2 = 0.99). The mean distance measured by the prototype was within 1.5 cm of the actual target distance for distances between 30 and 95 cm. The spectral energy of the indoor location was highest for the orange channel at about 100-160 counts/μW/cm2 , whereas it was highest for the blue channel in outdoor daylight (10,000-19,000 counts/μW/cm2 ).

Conclusion: A working prototype that can simultaneously measure the viewing distance, light intensity and spectral composition has been developed.

Keywords: light level; myopia; smart spectacles; spectral composition; viewing distance.

PubMed Disclaimer

References

REFERENCES

    1. Holden BA, Jong M, Davis S, Wilson D, Fricke T, Resnikoff S. Nearly 1 billion myopes at risk of myopia-related sight-threatening conditions by 2050-time to act now. Clin Exp Optom. 2015;98:491-3.
    1. Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology. 2016;123:1036-42.
    1. Xu L, Ma Y, Yuan J, Zhang Y, Wang H, Zhang G, et al. COVID-19 quarantine reveals that behavioural changes have an effect on myopia progression. Ophthalmology. 2021;128:1652-4.
    1. Sankaridurg P, Tahhan N, Kandel H, Naduvilath T, Zou H, Frick KD, et al. IMI impact of myopia. Invest Ophthalmol Vis Sci. 2021;62:ARVO E-Abstract 2.
    1. Huang HM, Chang DS, Wu PC. The association between near work activities and myopia in children-a systematic review and meta-analysis. PloS One. 2015;e0140419.https://doi.org/10.1371/journal.pone.0140419

Publication types

LinkOut - more resources