Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023;48(2):113-117.
doi: 10.1016/j.meddos.2023.01.006. Epub 2023 Mar 10.

The transition in practice to reduce bolus use in post-mastectomy radiotherapy: A dosimetric study of skin and subcutaneous tissue

Affiliations

The transition in practice to reduce bolus use in post-mastectomy radiotherapy: A dosimetric study of skin and subcutaneous tissue

Alexandra Guebert et al. Med Dosim. 2023.

Abstract

To inform clinical practice for women receiving post-mastectomy radiotherapy (PMRT), this study demonstrates the dosimetric impact of removing daily bolus on skin and subcutaneous tissue. Two planning strategies were used: clinical field-based (n = 30) and volume-based planning (n = 10). The clinical field-based plans were created with bolus and recalculated without bolus for comparison. The volume-based plans were created with bolus to ensure a minimum target coverage of the chest wall PTV and recalculated without bolus. In each scenario, the dose to superficial structures, including skin (3 mm and 5 mm) and subcutaneous tissue (a 2 mm layer, 3 mm deep from surface) were reported. Additionally, the difference in the clinically evaluated dosimetry to skin and subcutaneous tissue in volume-based plans were recalculated using Acuros (AXB) and compared to the Anisotropic Analytical Algorithm (AAA) algorithm. For all treatment planning strategies, chest wall coverage (V90%) was maintained. As expected, superficial structures demonstrate significant loss in coverage. The largest difference observed in the most superficial 3 mm where V90% coverage is reduced from a mean (± standard deviation) of 95.1% (± 2.8) to 18.9% (± 5.6) for clinical field-based treatments with and without bolus, respectively. For volume-based planning, the subcutaneous tissue maintains a V90% of 90.5% (± 7.0) compared to the clinical field-based planning coverage of 84.4% (± 8.0). In all skin and subcutaneous tissue, the AAA algorithm underestimates the volume of the 90% isodose. Removing bolus results in minimal dosimetric differences in the chest wall and significantly lower skin dose while dose to the subcutaneous tissue is maintained. Unless the skin has disease involvement, the most superficial 3 mm is not considered part of the target volume. The continued use of the AAA algorithm is supported for the PMRT setting.

Keywords: Bolus; Breast cancer; Post-mastectomy radiation therapy; Skin dose.

PubMed Disclaimer