Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul;50(8):2441-2452.
doi: 10.1007/s00259-023-06193-5. Epub 2023 Mar 18.

A multi-label CNN model for the automatic detection and segmentation of gliomas using [18F]FET PET imaging

Affiliations

A multi-label CNN model for the automatic detection and segmentation of gliomas using [18F]FET PET imaging

Masoomeh Rahimpour et al. Eur J Nucl Med Mol Imaging. 2023 Jul.

Abstract

Purpose: The aim of this study was to develop a convolutional neural network (CNN) for the automatic detection and segmentation of gliomas using [18F]fluoroethyl-L-tyrosine ([18F]FET) PET.

Methods: Ninety-three patients (84 in-house/7 external) who underwent a 20-40-min static [18F]FET PET scan were retrospectively included. Lesions and background regions were defined by two nuclear medicine physicians using the MIM software, such that delineations by one expert reader served as ground truth for training and testing the CNN model, while delineations by the second expert reader were used to evaluate inter-reader agreement. A multi-label CNN was developed to segment the lesion and background region while a single-label CNN was implemented for a lesion-only segmentation. Lesion detectability was evaluated by classifying [18F]FET PET scans as negative when no tumor was segmented and vice versa, while segmentation performance was assessed using the dice similarity coefficient (DSC) and segmented tumor volume. The quantitative accuracy was evaluated using the maximal and mean tumor to mean background uptake ratio (TBRmax/TBRmean). CNN models were trained and tested by a threefold cross-validation (CV) using the in-house data, while the external data was used for an independent evaluation to assess the generalizability of the two CNN models.

Results: Based on the threefold CV, the multi-label CNN model achieved 88.9% sensitivity and 96.5% precision for discriminating between positive and negative [18F]FET PET scans compared to a 35.3% sensitivity and 83.1% precision obtained with the single-label CNN model. In addition, the multi-label CNN allowed an accurate estimation of the maximal/mean lesion and mean background uptake, resulting in an accurate TBRmax/TBRmean estimation compared to a semi-automatic approach. In terms of lesion segmentation, the multi-label CNN model (DSC = 74.6 ± 23.1%) demonstrated equal performance as the single-label CNN model (DSC = 73.7 ± 23.2%) with tumor volumes estimated by the single-label and multi-label model (22.9 ± 23.6 ml and 23.1 ± 24.3 ml, respectively) closely approximating the tumor volumes estimated by the expert reader (24.1 ± 24.4 ml). DSCs of both CNN models were in line with the DSCs by the second expert reader compared with the lesion segmentations by the first expert reader, while detection and segmentation performance of both CNN models as determined with the in-house data were confirmed by the independent evaluation using external data.

Conclusion: The proposed multi-label CNN model detected positive [18F]FET PET scans with high sensitivity and precision. Once detected, an accurate tumor segmentation and estimation of background activity was achieved resulting in an automatic and accurate TBRmax/TBRmean estimation, such that user interaction and potential inter-reader variability can be minimized.

Keywords: CNN; Gliomas; Lesion detection; Lesion segmentation; Quantification; [18F]FET PET.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Albert NL, Weller M, Suchorska B, Galldiks N, Soffietti R, Kim MM, et al. Response Assessment in Neuro-Oncology working group and European Association for Neuro-Oncology recommendations for the clinical use of PET imaging in gliomas. Neuro-Oncol. 2016;18(9):1199–208. - DOI - PubMed - PMC
    1. Galldiks N, Langen KJ, Pope WB. From the clinician’s point of view-what is the status quo of positron emission tomography in patients with brain tumors? Neuro Oncol. 2015;17(11):1434–44. - DOI - PubMed - PMC
    1. Kobayashi K, Ohnishi A, Promsuk J, Shimizu S, Kanai Y, Shiokawa Y, et al. Enhanced tumor growth elicited by L-type amino acid transporter 1 in human malignant glioma cells. Neurosurgery. 2008;62(2):493–504. - DOI - PubMed
    1. Stöber B, Tanase U, Herz M, Seidl C, Schwaiger M, Senekowitsch-Schmidtke R. Differentiation of tumour and inflammation: characterisation of [methyl-3H] methionine (MET) and O-(2-[18F]fluoroethyl)-L-tyrosine (FET) uptake in human tumour and inflammatory cells. Eur J Nucl Med Mol Imaging. 2006;33(8):932–9. - DOI - PubMed
    1. Lahoutte T, Caveliers V, Camargo SM, Franca R, Ramadan T, Veljkovic E, et al. SPECT and PET amino acid tracer influx via system L (h4F2hc-hLAT1) and its transstimulation. J Nucl Med. 2004;45(9):1591–6. - PubMed

LinkOut - more resources