A multi-label CNN model for the automatic detection and segmentation of gliomas using [18F]FET PET imaging
- PMID: 36933075
- DOI: 10.1007/s00259-023-06193-5
A multi-label CNN model for the automatic detection and segmentation of gliomas using [18F]FET PET imaging
Abstract
Purpose: The aim of this study was to develop a convolutional neural network (CNN) for the automatic detection and segmentation of gliomas using [18F]fluoroethyl-L-tyrosine ([18F]FET) PET.
Methods: Ninety-three patients (84 in-house/7 external) who underwent a 20-40-min static [18F]FET PET scan were retrospectively included. Lesions and background regions were defined by two nuclear medicine physicians using the MIM software, such that delineations by one expert reader served as ground truth for training and testing the CNN model, while delineations by the second expert reader were used to evaluate inter-reader agreement. A multi-label CNN was developed to segment the lesion and background region while a single-label CNN was implemented for a lesion-only segmentation. Lesion detectability was evaluated by classifying [18F]FET PET scans as negative when no tumor was segmented and vice versa, while segmentation performance was assessed using the dice similarity coefficient (DSC) and segmented tumor volume. The quantitative accuracy was evaluated using the maximal and mean tumor to mean background uptake ratio (TBRmax/TBRmean). CNN models were trained and tested by a threefold cross-validation (CV) using the in-house data, while the external data was used for an independent evaluation to assess the generalizability of the two CNN models.
Results: Based on the threefold CV, the multi-label CNN model achieved 88.9% sensitivity and 96.5% precision for discriminating between positive and negative [18F]FET PET scans compared to a 35.3% sensitivity and 83.1% precision obtained with the single-label CNN model. In addition, the multi-label CNN allowed an accurate estimation of the maximal/mean lesion and mean background uptake, resulting in an accurate TBRmax/TBRmean estimation compared to a semi-automatic approach. In terms of lesion segmentation, the multi-label CNN model (DSC = 74.6 ± 23.1%) demonstrated equal performance as the single-label CNN model (DSC = 73.7 ± 23.2%) with tumor volumes estimated by the single-label and multi-label model (22.9 ± 23.6 ml and 23.1 ± 24.3 ml, respectively) closely approximating the tumor volumes estimated by the expert reader (24.1 ± 24.4 ml). DSCs of both CNN models were in line with the DSCs by the second expert reader compared with the lesion segmentations by the first expert reader, while detection and segmentation performance of both CNN models as determined with the in-house data were confirmed by the independent evaluation using external data.
Conclusion: The proposed multi-label CNN model detected positive [18F]FET PET scans with high sensitivity and precision. Once detected, an accurate tumor segmentation and estimation of background activity was achieved resulting in an automatic and accurate TBRmax/TBRmean estimation, such that user interaction and potential inter-reader variability can be minimized.
Keywords: CNN; Gliomas; Lesion detection; Lesion segmentation; Quantification; [18F]FET PET.
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Similar articles
-
Automatic lesion detection and segmentation of 18F-FET PET in gliomas: A full 3D U-Net convolutional neural network study.PLoS One. 2018 Apr 13;13(4):e0195798. doi: 10.1371/journal.pone.0195798. eCollection 2018. PLoS One. 2018. PMID: 29652908 Free PMC article.
-
Static 18F-FET PET and DSC-PWI based on hybrid PET/MR for the prediction of gliomas defined by IDH and 1p/19q status.Eur Radiol. 2021 Jun;31(6):4087-4096. doi: 10.1007/s00330-020-07470-9. Epub 2020 Nov 19. Eur Radiol. 2021. PMID: 33211141
-
An External, Independent Validation of an O-(2-[18F]Fluoroethyl)-l-Tyrosine PET Automatic Segmentation Network on a Single-Center, Prospective Dataset of Patients with Glioblastoma.J Nucl Med. 2025 Jun 2;66(6):948-953. doi: 10.2967/jnumed.124.268925. J Nucl Med. 2025. PMID: 40180564
-
Early static (18)F-FET-PET scans have a higher accuracy for glioma grading than the standard 20-40 min scans.Eur J Nucl Med Mol Imaging. 2016 Jun;43(6):1105-14. doi: 10.1007/s00259-015-3276-2. Epub 2015 Dec 15. Eur J Nucl Med Mol Imaging. 2016. PMID: 26666239
-
Automated Brain Tumor Detection and Segmentation for Treatment Response Assessment Using Amino Acid PET.J Nucl Med. 2023 Oct;64(10):1594-1602. doi: 10.2967/jnumed.123.265725. Epub 2023 Aug 10. J Nucl Med. 2023. PMID: 37562802
Cited by
-
A multimodal deep-learning model based on multichannel CT radiomics for predicting pathological grade of bladder cancer.Abdom Radiol (NY). 2025 Jul;50(7):3049-3059. doi: 10.1007/s00261-024-04748-0. Epub 2024 Dec 18. Abdom Radiol (NY). 2025. PMID: 39690281 Review.
-
Deep learning in nuclear medicine: from imaging to therapy.Ann Nucl Med. 2025 May;39(5):424-440. doi: 10.1007/s12149-025-02031-w. Epub 2025 Mar 13. Ann Nucl Med. 2025. PMID: 40080372 Review.
-
Interobserver ground-truth variability limits performance of automated glioblastoma segmentation on [18F]FET PET.EJNMMI Phys. 2025 Jun 6;12(1):54. doi: 10.1186/s40658-025-00767-y. EJNMMI Phys. 2025. PMID: 40478497 Free PMC article.
References
-
- Stöber B, Tanase U, Herz M, Seidl C, Schwaiger M, Senekowitsch-Schmidtke R. Differentiation of tumour and inflammation: characterisation of [methyl-3H] methionine (MET) and O-(2-[18F]fluoroethyl)-L-tyrosine (FET) uptake in human tumour and inflammatory cells. Eur J Nucl Med Mol Imaging. 2006;33(8):932–9. - DOI - PubMed
-
- Lahoutte T, Caveliers V, Camargo SM, Franca R, Ramadan T, Veljkovic E, et al. SPECT and PET amino acid tracer influx via system L (h4F2hc-hLAT1) and its transstimulation. J Nucl Med. 2004;45(9):1591–6. - PubMed
MeSH terms
Substances
Grants and funding