Purpose: To evaluate the utility of dual energy CT angiography (DECTA) in acute non-variceal gastrointestinal hemorrhage (ANVGIH) compared to digital subtraction angiography (DSA) as gold standard.
Materials and methods: 111 Patients (mean age: 39.2 years; 94 males) of ANVGIH who underwent both DECTA and DSA between January 2016 and September 2021 were included. Virtual monochromatic (VM) images at 10 keV increments from 40 to 70 keV and blended (120kVp equivalent) images of arterial phase of DECTA were evaluated independently by two readers blinded to DSA information. Quantitative analysis included measurement of attenuation in the major arteries (abdominal aorta, celiac artery, superior mesenteric artery), suspected vascular lesion, and lesion feeding artery to calculate contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs). Qualitative analysis assessed the image quality of each data set using a 3-point Likert scale. Findings on DSA were evaluated by a third reader and both DECTA and DSA were compared.
Results: On linear blended images, vascular lesion was identified by reader 1 in 88 (79.3%) and by reader 2 in 87 (78.4%) patients and DSA showed lesion in 92 (82.9%) patients. The sensitivity and specificity of blended images and VM images of DECTA for lesion detection were not significantly different from each other. The CNR and SNR of arteries, vascular lesion and feeding artery were significantly higher at 70 keV (p < 0.005) compared to blended and other VM images. Although subjective scores for image quality were higher for 60 keV images by both readers, the difference was not statistically significant (p = 0.3). The interobserver agreement was mostly good.
Conclusion: In the assessment of ANVGIH, the 60 keV and 70 keV VM images improved the image quality and contrast, respectively, but there was no increase in diagnostic accuracy of VM image datasets compared to linearly blended images. Hence, the diagnostic utility of DECTA in ANVGIH is still uncertain.
Keywords: Angiography; Dual energy CT; Gastrointestinal hemorrhage; Spectral CT; Virtual monoenergetic.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Similar articles
-
Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.Invest Radiol. 2016 Feb;51(2):139-46. doi: 10.1097/RLI.0000000000000216. Invest Radiol. 2016. PMID: 26561048
-
Image quality improvement in head and neck angiography based on dual-energy CT and deep learning.BMC Med Imaging. 2025 Apr 10;25(1):115. doi: 10.1186/s12880-025-01659-4. BMC Med Imaging. 2025. PMID: 40211222 Free PMC article.
-
Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast.Eur Radiol. 2016 Jun;26(6):1863-70. doi: 10.1007/s00330-015-3970-2. Epub 2015 Sep 3. Eur Radiol. 2016. PMID: 26334508
-
Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.Eur Radiol. 2017 Feb;27(2):705-714. doi: 10.1007/s00330-016-4422-3. Epub 2016 May 28. Eur Radiol. 2017. PMID: 27236818
-
Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.Invest Radiol. 2016 Sep;51(9):582-90. doi: 10.1097/RLI.0000000000000272. Invest Radiol. 2016. PMID: 26953565
Cited by
-
Comparison of split bolus dual energy CT and standard multiphase CT in assessing vascular invasion in patients with biliary malignancies: a randomized study.Abdom Radiol (NY). 2025 Jul 11. doi: 10.1007/s00261-025-05111-7. Online ahead of print. Abdom Radiol (NY). 2025. PMID: 40643653
References
MeSH terms
LinkOut - more resources
Full Text Sources