Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system
- PMID: 3695618
- DOI: 10.1007/BF02442844
Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system
Similar articles
-
Comparison of EASI-derived 12-lead electrocardiograms versus paramedic-acquired 12-lead electrocardiograms using Mason-Likar limb lead configuration in patients with chest pain.J Electrocardiol. 2006 Jan;39(1):13-21. doi: 10.1016/j.jelectrocard.2005.05.011. Epub 2005 Nov 9. J Electrocardiol. 2006. PMID: 16387044
-
A simple measure to control for variations in chest electrodes placement in serial electrocardiogram recordings.J Electrocardiol. 2008 Sep-Oct;41(5):378-9. doi: 10.1016/j.jelectrocard.2008.05.008. Epub 2008 Jul 11. J Electrocardiol. 2008. PMID: 18620704
-
Modified axial lead system in children.Br Heart J. 1977 Oct;39(10):1102-8. doi: 10.1136/hrt.39.10.1102. Br Heart J. 1977. PMID: 911562 Free PMC article.
-
A technicians' perspective: tips and techniques for using disposable tab electrocardiogram electrodes; an easy to remember method for preventing electrocardiogram lead interchange.J Electrocardiol. 2006 Oct;39(4):355-7. doi: 10.1016/j.jelectrocard.2006.03.007. Epub 2006 May 12. J Electrocardiol. 2006. PMID: 16697398 Review. No abstract available.
-
Vectorcardiographic diagnostic & prognostic information derived from the 12-lead electrocardiogram: Historical review and clinical perspective.J Electrocardiol. 2015 Jul-Aug;48(4):463-75. doi: 10.1016/j.jelectrocard.2015.05.002. Epub 2015 May 8. J Electrocardiol. 2015. PMID: 26027545 Review.
Cited by
-
Advanced Bioelectrical Signal Processing Methods: Past, Present and Future Approach-Part I: Cardiac Signals.Sensors (Basel). 2021 Jul 30;21(15):5186. doi: 10.3390/s21155186. Sensors (Basel). 2021. PMID: 34372424 Free PMC article. Review.
-
Statistical Evaluation of Transformation Methods Accuracy on Derived Pathological Vectorcardiographic Leads.IEEE J Transl Eng Health Med. 2022 Apr 13;10:1900208. doi: 10.1109/JTEHM.2022.3167009. eCollection 2022. IEEE J Transl Eng Health Med. 2022. PMID: 35769406 Free PMC article.
-
Spatiotemporal representation of cardiac vectorcardiogram (VCG) signals.Biomed Eng Online. 2012 Mar 30;11:16. doi: 10.1186/1475-925X-11-16. Biomed Eng Online. 2012. PMID: 22463593 Free PMC article.
-
Real time electrocardiogram QRS detection using combined adaptive threshold.Biomed Eng Online. 2004 Aug 27;3(1):28. doi: 10.1186/1475-925X-3-28. Biomed Eng Online. 2004. PMID: 15333132 Free PMC article.
-
Comparison of Different Electrocardiography with Vectorcardiography Transformations.Sensors (Basel). 2019 Jul 11;19(14):3072. doi: 10.3390/s19143072. Sensors (Basel). 2019. PMID: 31336798 Free PMC article.
References
MeSH terms
LinkOut - more resources
Other Literature Sources