Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Apr 12;44(4).
doi: 10.1088/1361-6579/acc725.

Photoplethysmography wave morphology in patients with atrial fibrillation

Affiliations

Photoplethysmography wave morphology in patients with atrial fibrillation

Mikołaj Basza et al. Physiol Meas. .

Abstract

Objective.Most current algorithms for detecting atrial fibrillation (AF) rely on heart rate variability (HRV), and only a few studies analyse the variability of photopletysmography (PPG) waveform. This study aimed to compare morphological features of the PPG curve in patients with AF to those presenting a normal sinus rhythm (NSR) and evaluate their usefulness in AF detection.Approach.10 min PPG signals were obtained from patients with persistent/paroxysmal AF and NSR. Nine morphological parameters (1/ΔT), Pulse Width [PW], augmentation index [AI], b/a, e/a, [b-e]/a, crest time [CT], inflection point area [IPA], Area and five HRV parameters (heart rate [HR], Shannon entropy [ShE], root mean square of the successive differences [RMSSD], number of pairs of consecutive systolic peaks [R-R] that differ by more than 50 ms [NN50], standard deviation of theR-Rintervals [SDNN]) were calculated.Main results.Eighty subjects, including 33 with AF and 47 with NSR were recruited. In univariate analysis five morphological features (1/ΔT,p< 0.001; b/a,p< 0.001; [b-e]/a,p< 0.001; CT,p= 0.011 and Area,p< 0.001) and all HRV parameters (p= 0.01 for HR andp< 0.001 for others) were significantly different between the study groups. In the stepwise multivariate model (Area under the curve [AUC] = 0.988 [0.974-1.000]), three morphological parameters (PW,p< 0.001; e/a,p= 0.011; (b-e)/a,p< 0.001) and three of HRV parameters (ShE,p= 0.01; NN50,p< 0.001, HR,p= 0.01) were significant.Significance.There are significant differences between AF and NSR, PPG waveform, which are useful in AF detection algorithm. Moreover adding those features to HRV-based algorithms may improve their specificity and sensitivity.

Keywords: algorithm; atrial fibrillation; heart rate variability; photoplethysmography; screening.

PubMed Disclaimer

LinkOut - more resources