Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Sep;42(9):2065-2072.
doi: 10.1002/jum.16226. Epub 2023 Mar 27.

Ultrasonographic Patterns of Calcium Hydroxyapatite According to Dilution and Mix With Hyaluronic Acid

Affiliations

Ultrasonographic Patterns of Calcium Hydroxyapatite According to Dilution and Mix With Hyaluronic Acid

Ximena Wortsman et al. J Ultrasound Med. 2023 Sep.

Abstract

Objectives: To assess the ultrasonographic patterns of different calcium hydroxyapatite (CaHA) formulations, including the undiluted, diluted, and mixed with hyaluronic acid (HA) compounds.

Methods: To review the ultrasonographic images of patients ≥18 years with confirmed injections of CaHA clinically and ultrasonographically, and without different concomitant types of fillers in the same region or other systemic or localized cutaneous diseases.

Results: Twenty-one patients met the criteria (90% female; 10% male; mean age: 52 years ± 12.8). Of these, 33.3% have been injected with an undiluted formulation, 33.3% with diluted, and 33.3% with a mixed formulation. All cases were studied with devices presenting frequencies that ranged from 18 to 24 MHz. Twelve cases (57%) were also studied with the 70 MHz. The ultrasonographic patterns of CaHA presented differences in the presence and intensity of PAS and the degree of inflammation according to the dilution and mix with HA. Diluted formulations show a milder intensity posterior acoustic shadowing (PAS) artifact than undiluted at 18-24 MHz. In mixed formulations, 57% showed mild PAS, and 43% demonstrated no PAS artifact at 18-24 MHz, besides fewer inflammatory changes in the periphery of the deposits.

Conclusions: The ultrasonographic patterns of CaHA show differences in the presence and intensity of PAS and the degree of inflammation according to the dilution and mix with HA. Awareness of these ultrasonographic variations can support better discrimination of CaHA.

Keywords: aesthetics ultrasound; calcium hydroxyapatite ultrasound; dermatologic ultrasound; fillers ultrasound; skin ultrasound.

PubMed Disclaimer

References

    1. Cohen SR, Patton S, Wesson J, Tiryaki KT, Mora A. Radiesse rescue: a preliminary study for a simple and effective technique for the removal of calcium hydroxyapatite-based fillers. Aesthet Surg J 2023; 43:365-369. https://doi.org/10.1093/asj/sjac299.
    1. Corduff N, Chen JF, Chen YH, et al. Pan-Asian consensus on calcium hydroxyapatite for skin biostimulation, contouring, and combination treatments. J Clin Aesthet Dermatol 2021; 14:e76-e85.
    1. de Almeida AT, Figueredo V, da Cunha ALG, et al. Consensus recommendations for the use of Hyperdiluted calcium hydroxyapatite (Radiesse) as a face and body biostimulatory agent. Plast Reconstr Surg Glob Open 2019; 7:e2160. https://doi.org/10.1097/gox.0000000000002160.
    1. Emer J, Sundaram H. Aesthetic applications of calcium hydroxylapatite volumizing filler: an evidence-based review and discussion of current concepts: (part 1 of 2). J Drugs Dermatol 2013; 12:1345-1354.
    1. Goldie K, Peeters W, Alghoul M, et al. Global consensus guidelines for the injection of diluted and hyperdiluted calcium hydroxylapatite for skin tightening. Dermatol Surg 2018; 44:S32-s41. https://doi.org/10.1097/dss.0000000000001685.