Thoracic endovascular aortic repair has become the preferred modality of treatment of complicated type B aortic dissections. However, persistent pressurization of the false lumen can lead to negative aortic remodeling with aneurysmal dilation. Described herein is the coil embolization technique that can be used to manage this complication and a review of the literature on the recent development of management options.
Computed tomography angiogram of the thorax shows the type B aortic dissection. Supplemental…
Fig. 1
Computed tomography angiogram of the thorax shows the type B aortic dissection. Supplemental motion image is available for Figure 1.
Fig. 2
Sagittal view of the computed…
Fig. 2
Sagittal view of the computed tomography angiogram of the thorax shows the type…
Fig. 2
Sagittal view of the computed tomography angiogram of the thorax shows the type B aortic dissection.
Fig. 3
Computed tomography angiogram shows the…
Fig. 3
Computed tomography angiogram shows the type Ib endoleak with resultant aneurysmal dilation from…
Fig. 3
Computed tomography angiogram shows the type Ib endoleak with resultant aneurysmal dilation from false lumen pressurization. Supplemental motion image is available for Figure 3.
Fig. 4
Intraoperative aortogram shows type Ib…
Fig. 4
Intraoperative aortogram shows type Ib endoleak before coil placement.
Fig. 4
Intraoperative aortogram shows type Ib endoleak before coil placement.
Fig. 5
Aortogram after placement of additional…
Fig. 5
Aortogram after placement of additional distal thoracic stent graft and coil embolization of…
Fig. 5
Aortogram after placement of additional distal thoracic stent graft and coil embolization of the false lumen.
Moulakakis KG, Mylonas SN, Dalainas I, Kakisis J, Kotsis T, Liapis CD. Management of complicated and uncomplicated acute type B dissection. A systematic review and meta-analysis. Ann Cardiothorac Surg . 2014;3(3):234–246. doi: 10.3978/j.issn.2225-319X.2014.05.08.
-
DOI
-
PMC
-
PubMed
Nienaber CA, Rousseau H, Eggebrecht H et al. Randomized comparison of strategies for type B aortic dissection: the INvestigation of STEnt Grafts in Aortic Dissection (INSTEAD) trial. Circulation . 2009;120(25):2519–2528. doi: 10.1161/CIRCULATIONAHA.109.886408.
-
DOI
-
PubMed
Tanaka A, Sakakibara M, Ishii H et al. Influence of the false lumen status on clinical outcomes in patients with acute type B aortic dissection. J Vasc Surg . 2014;59(2):321–326. doi: 10.1016/j.jvs.2013.08.031.
-
DOI
-
PubMed
Lombardi JV, Hughes GC, Appoo JJ et al. Society for Vascular Surgery (SVS) and Society of Thoracic Surgeons (STS) reporting standards for type B aortic dissections. Ann Thorac Surg . 2020;109(3):959–981. doi: 10.1016/j.athoracsur.2019.10.005.
-
DOI
-
PubMed
Kölbel T, Lohrenz C, Kieback A, Diener H, Debus ES, Larena-Avellaneda A. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther . 2013;20(4):484–489. doi: 10.1583/13-4318.1.
-