False-positive magnetic resonance imaging prostate cancer correlates and clinical implications
- PMID: 37006206
- PMCID: PMC10062519
- DOI: 10.4103/ua.ua_22_22
False-positive magnetic resonance imaging prostate cancer correlates and clinical implications
Abstract
Background: False-positive (FP) multiparametric magnetic resonance imaging (MPMRI) obscures and swift needless biopsies in men with a high prostate-specific antigen.
Materials and methods: This was a retrospective study, in which all patients who had been exposed to consecutive MP-MRI of the prostate combined with transrectal ultrasound-guided-magnetic resonance imaging fusion-guided prostate biopsy between 2017 and 2020 were involved in the study. The FP was measured as the number of biopsies that did not encompass prostate cancer divided by the whole number of biopsies.
Results: The percentage of FP cases was 51.1%, the highest percentage was found in Prostate Imaging-Reporting and Data System (PI-RADs) 3 (37.7%) and the lowest was detected in PI-RAD 5 (14.5%). Those with FP biopsies are younger, and their total prostate antigen (PSA) and PSA density (PSAD) are significantly lesser. The area under the curve PSAD, age, and total PSA are 0.76, 0.74, and 0.69, respectively. An optimum PSAD value of 0.135 was chosen as a cutoff because it showed the highest sum of sensitivity and specificity, 68% and 69%, respectively.
Conclusion: FP results of mpMRI were detected in more than half of our sample, more than one-third were presented in Pi-RAD3, improved imaging techniques to decrease FP rates are highly needed.
Keywords: PIRADs; prostate cancer; transrectal ultrasound-guided biopsy- magnetic resonance imaging fusion-guided prostate biopsy.
Copyright: © 2022 Urology Annals.
Conflict of interest statement
There are no conflicts of interest.
Figures
References
-
- Abraham NE, Mendhiratta N, Taneja SS. Patterns of repeat prostate biopsy in contemporary clinical practice. J Urol. 2015;193:1178–84. - PubMed
-
- Loeb S, Vellekoop A, Ahmed HU, Catto J, Emberton M, Nam R, et al. Systematic review of complications of prostate biopsy. Eur Urol. 2013;64:876–92. - PubMed
-
- Mowatt G, Scotland G, Boachie C, Cruickshank M, Ford JA, Fraser C, et al. The diagnostic accuracy and cost-effectiveness of magnetic resonance spectroscopy and enhanced magnetic resonance imaging techniques in aiding the localisation of prostate abnormalities for biopsy: A systematic review and economic evaluation. Health Technol Assess. 2013;17 vii-xix, 1-281. - PMC - PubMed
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous