Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Mar 29:S0020-1383(23)00289-9.
doi: 10.1016/j.injury.2023.03.033. Online ahead of print.

Mid-term functional outcome (minimum 24 months, mean 4 years) after locking plate osteosynthesis for displaced fractures of the proximal humerus in 557 cases

Affiliations

Mid-term functional outcome (minimum 24 months, mean 4 years) after locking plate osteosynthesis for displaced fractures of the proximal humerus in 557 cases

Rouven Neudeck et al. Injury. .

Abstract

Background: The best surgical management of displaced proximal humeral fractures remains a matter of considerable debate. This study presents mid-term functional outcome (median 4 years) after locking plate osteosynthesis for displaced proximal humeral fractures.

Methods: Between February 2002 and December 2014 1031 patients with 1047 displaced proximal humeral fractures were treated by open reduction and locking plate fixation with the same implant and received consecutive prospective follow up at least 24 months after surgical treatment. Clinical follow-up consisted of Constant Murley score (CS), Disabilities of the Arm, Shoulder and Hand score (DASH), and Short Form 36 questionnaire (SF-36). Complete follow-up could be performed in 557 (53.2%) cases, with a mean follow-up of 4.0 ± 2.7 years.

Results: Of 557 patients (67% women; mean age at time of osteosynthesis: 68.3 ± 15.5 years) absolute CS of all patients 4 ± 2.7 years after surgery was 68.4 ± 20.3 points. Normalized CS according to Katolik was 80.4 ± 23.8 points, and CS in percentage to the contralateral side (%CS) was 87.2 ± 27.9%. DASH score was at 23.8 ± 20.8 points. Osteosynthesis related complications (secondary displacement, screw cutout, avascular necrosis (n = 117 patients) were associated with lower functional scores (mean CS was 54.5 ± 19.0 p.; nCS 64.5 ± 22.9 p.;%CS 71.2 ± 25.0%; DASH score 31.9 ± 22.4 p.). The SF 36 was 66.5 points in the case cohort and a vitality mean of 69.4 points. Patients with a complication showed lower results (SF 36 56.7; vitality mean 64.9 points).

Conclusions: Overall, patients following locking plate osteosynthesis of displaced proximal humeral fractures showed good to moderate outcomes four years after surgery. Mid-term functional outcomes correlate significantly with those at 1 year postoperatively. Furthermore, there is a significant negative correlation of midterm functional outcome with the occurrence of complications.

Level of evidence: Level III, prospective nonconsecutive patients.

Keywords: Constant score; DASH-score; Functional outcome; Locked plating; Mid-term; Proximal humeral fracture; SF-36.