Cerebrospinal Fluid Flow and Brain Motion in Chiari I Malformation: Past, Present, and Future
- PMID: 37013364
- DOI: 10.1002/jmri.28717
Cerebrospinal Fluid Flow and Brain Motion in Chiari I Malformation: Past, Present, and Future
Abstract
Cranio-spinal volume and pressure changes associated with the cardiac-cycle and respiration are altered in Chiari I malformation (CMI) due to obstruction of cerebrospinal fluid (CSF) flow at the foramen magnum. With the introduction of motion-sensitive MRI sequences, it was envisioned that these could provide noninvasive information about volume-pressure dynamics at the cranio-cervical junction in CMI hitherto available only through invasive pressure measurements. Since the early 1990s, multiple studies have assessed CSF flow and brain motion in CMI. However, differences in design and varied approaches in the presentation of results and conclusions makes it difficult to fully comprehend the role of MR imaging of CSF flow and brain motion in CMI. In this review, a cohesive summary of the current status of MRI assessment of CSF flow and brain motion in CMI is presented. Simplified versions of the results and conclusions of previous studies are presented by dividing the studies in distinct topics: 1) comparing CSF flow and brain motion between healthy subjects (HS) and CMI patients (before and after surgery), 2) comparing CSF flow and brain motion to CMI severity and symptoms, and 3) comparing CSF flow and brain motion in CMI with and without syringomyelia. Finally, we will discuss our vision of the future directions of MR imaging in CMI patients. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: 5.
Keywords: CSF flow; Chiari I malformation; MRI; brain motion.
© 2023 International Society for Magnetic Resonance in Medicine.
References
-
- Elster AD, Chen MY. Chiari I malformations: Clinical and radiologic reappraisal. Radiology 1992;183(2):347-353.
-
- Meadows J, Kraut M, Guarnieri M, Haroun RI, Carson BS. Asymptomatic Chiari type I malformations identified on magnetic resonance imaging. J Neurosurg 2000;92(6):920-926.
-
- Alperin N, Kulkarni K, Roitberg B, et al. Analysis of magnetic resonance imaging-based blood and cerebrospinal fluid flow measurements in patients with Chiari I malformation: A system approach. Neurosurg Focus 2001;11(1):E6-E10.
-
- Alperin N, Sivaramakrishnan A, Lichtor T. Magnetic resonance imaging-based measurements of cerebrospinal fluid and blood flow as indicators of intracranial compliance in patients with Chiari malformation. J Neurosurg 2005;103(1):46-52.
-
- Armonda RA, Citrin CM, Foley KT, Ellenbogen RG. Quantitative cine-mode magnetic resonance imaging of Chiari I malformations: An analysis of cerebrospinal fluid dynamics. Neurosurgery 1994;35(2):214-224.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous