Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May:152:111557.
doi: 10.1016/j.jbiomech.2023.111557. Epub 2023 Mar 27.

A digital twin framework for robust control of robotic-biological systems

Affiliations
Free article

A digital twin framework for robust control of robotic-biological systems

Alastair R J Quinn et al. J Biomech. 2023 May.
Free article

Abstract

Medical device regulatory standards are increasingly incorporating computational modelling and simulation to accommodate advanced manufacturing and device personalization. We present a method for robust testing of engineered soft tissue products involving a digital twin paradigm in combination with robotic systems. We developed and validated a digital twin framework for calibrating and controlling robotic-biological systems. A forward dynamics model of the robotic manipulator was developed, calibrated, and validated. After calibration, the accuracy of the digital twin in reproducing the experimental data improved in the time domain for all fourteen tested configurations and improved in frequency domain for nine configurations. We then demonstrated displacement control of a spring in lieu of a soft tissue element in a biological specimen. The simulated experiment matched the physical experiment with 0.09 mm (0.001%) root-mean-square error for a 2.9 mm (5.1%) length change. Finally, we demonstrated kinematic control of a digital twin of the knee through 70-degree passive flexion kinematics. The root-mean-square error was 2.00°, 0.57°, and 1.75° degrees for flexion, adduction, and internal rotations, respectively. The system well controlled novel mechanical elements and generated accurate kinematics in silico for a complex knee model. This calibration method could be applied to other situations where the specimen is poorly represented in the model environment (e.g., human or animal tissues), and the control system could be extended to track internal parameters such as tissue strain (e.g., control knee ligament strain). Further development of this framework can facilitate medical device testing and innovative biomechanics research.

Keywords: Biomechanics; Control; Musculoskeletal; Orthopaedic; Simulation.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types

LinkOut - more resources