Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Apr;128(4):480-491.
doi: 10.1007/s11547-023-01620-x. Epub 2023 Apr 7.

Utility of virtual stenting in treatment of cerebral aneurysms by flow diverter devices

Affiliations

Utility of virtual stenting in treatment of cerebral aneurysms by flow diverter devices

Francesco Briganti et al. Radiol Med. 2023 Apr.

Abstract

Successful endovascular treatment by stenting of intracranial aneurysms requires proper placement of the device and appropriate choice of its diameter and length. To date, several methods have been employed to achieve these goals, although each has inherent critical issues. Recently developed stent planning software applications can be used to assist interventional neuroradiologists. Based on a 3D-DSA image acquired before stenting, these applications simulate and visualize the final placement of the deployed stent. In this single-centre retrospective study, 27 patients undergoing an intravascular procedure for the treatment of intracranial aneurysms from June 2019 to July 2020 were evaluated according to strict inclusion criteria. Stent virtualization was performed with Syngo 3D Aneurysm Guidance Neuro software. We compared the software-generated stent measurement and measurements taken by the interventional radiologist. Statistical analysis was performed using the STAC web platform. Mean and standard deviations of absolute and relative discrepancies between predicted and implanted stents were recorded. Friedman's nonparametric test was used to refute the null hypotheses, i.e. (I) discrepancies between the size of virtual and implanted stents would occur, and (II) operator influence does not affect the outcome of the virtual stenting process. Based on these observations, it is believed that the virtual stenting process can validly assist interventional neuroradiologists in selecting the appropriate device and reducing peri- and post-procedural complications. The results of our study suggest that virtual reality simulation of devices used for endovascular treatment of intracranial aneurysms is a useful, rapid, and accurate tool for interventional procedure planning.

Keywords: Aneurysm; Cerebral artery; Interventional neuroradiology; Stent; Virtual stenting.

PubMed Disclaimer

References

    1. Bouillot P, Brina O, Yilmaz H et al (2016) Virtual-versus-real implantation of flow diverters: clinical potential and influence of vascular geometry. AJNR Am J Neuroradiol 37(11):2079–2086. https://doi.org/10.3174/ajnr.A4845 - DOI - PubMed - PMC
    1. Ouared R, Larrabide I, Brina O et al (2016) Computational fluid dynamics analysis of flow reduction induced by flow-diverting stents in intracranial aneurysms: a patient-unspecific hemodynamics change perspective. J Neurointerv Surg 8(12):1288–1293. https://doi.org/10.1136/neurintsurg-2015-012154 - DOI - PubMed
    1. Kulcsár Z, Augsburger L, Reymond P et al (2012) Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis. Acta Neurochir (Wien) 154(10):1827–1834. https://doi.org/10.1007/s00701-012-1482-2 - DOI - PubMed
    1. Mut F, Raschi M, Scrivano E et al (2015) Association between hemodynamic conditions and occlusion times after flow diversion in cerebral aneurysms. J Neurointerv Surg 7(4):286–290. https://doi.org/10.1136/neurintsurg-2013-011080 - DOI - PubMed
    1. Kellermann R, Serowy S, Beuing O, Skalej M (2019) Deployment of flow diverter devices: prediction of foreshortening and validation of the simulation in 18 clinical cases. Neuroradiology 61(11):1319–1326. https://doi.org/10.1007/s00234-019-02287-w - DOI - PubMed

LinkOut - more resources