Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul:175:e704-e712.
doi: 10.1016/j.wneu.2023.04.009. Epub 2023 Apr 11.

The Significance of the Intercarotid Distances for Transsphenoidal Pituitary Surgery: A Magnetic Resonance Imaging Study

Affiliations

The Significance of the Intercarotid Distances for Transsphenoidal Pituitary Surgery: A Magnetic Resonance Imaging Study

Haruka Tsuneoka et al. World Neurosurg. 2023 Jul.

Abstract

Objective: We performed magnetic resonance imaging (MRI) to analyze the distance between the left and right internal carotid arteries (ICD) around pituitary tumors for transsphenoidal surgery (TSS).

Methods: Measurements were performed using thin slice T2-weighted MRI, and/or time-of-flight (TOI) MR angiography imaging for 64 nonfunctioning pituitary neuroendocrine tumors (NF-pitNETs), 22 growth hormone-producing pitNETs (GH producing pitNETs), and 46 normal controls. We measured the ICD at 3 anatomic levels: at the distal dural ring (ICD-A); at the most concave point of the C4-C5 bend (ICD-B); and at the most convex point of the C4 bend (ICD-C). Additionally, we measured the sagittal distance between the tuberculum selle and the junction of the sellar floor and clivus on the midsagittal MRI (TS-C).

Results: We found that ICD-B was the longest and that ICD-A was the shortest among the 3 distance parameters in all groups (P < 0.001). The comparison of the groups revealed that the NF-pitNET group had longer distances than the normal control group at all ICDs (P < 0.001). The GH producing pitNET group had longer distance than the normal control group at ICD-B (P < 0.001). Tumor volume was correlated with ICD-A and ICD-B in the NF-pitNET, and was correlated with ICD-C in the GH producing pitNET group.

Conclusions: Among the distance parameters, ICD-B is the longest, and was approximately twice the width of the TS-C. The shape of the sella is an ellipse that is widest in the lateral dimension in TSS. A horizontal based dural incision may be more rational than a conventional X-shaped dural incision.

Keywords: Intercarotid distance; PitNET; Transsphenoidal surgery.

PubMed Disclaimer

MeSH terms

LinkOut - more resources