Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2023 Apr 4;24(7):6740.
doi: 10.3390/ijms24076740.

The Potential Use of Near- and Mid-Infrared Spectroscopy in Kidney Diseases

Affiliations
Review

The Potential Use of Near- and Mid-Infrared Spectroscopy in Kidney Diseases

Charlotte Delrue et al. Int J Mol Sci. .

Abstract

Traditional renal biomarkers such as serum creatinine and albuminuria/proteinuria are rather insensitive since they change later in the course of the disease. In order to determine the extent and type of kidney injury, as well as to administer the proper therapy and enhance patient management, new techniques for the detection of deterioration of the kidney function are urgently needed. Infrared spectroscopy is a label-free and non-destructive technique having the potential to be a vital tool for quick and inexpensive routine clinical diagnosis of kidney disorders. The aim of this review is to provide an overview of near- and mid-infrared spectroscopy applications in patients with acute kidney injury and chronic kidney disease (e.g., diabetic nephropathy and glomerulonephritis).

Keywords: attenuated total reflectance-Fourier-transform infrared spectroscopy; infrared spectroscopy; kidney diseases; mid-infrared; near-infrared.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Typical MIR spectrum measured using attenuated total reflection–Fourier transform infrared (ATR–FTIR) spectroscopy of a biological sample showing peak assignments from 4000 to 800 cm−1. V: stretching vibrations, δ: bending vibrations, s: symmetric vibrations, as: asymmetric vibrations.

Similar articles

Cited by

References

    1. Krstic D., Tomic N., Radosavljevic B., Avramovic N., Dragutinovic V., Skodric S.R., Colovic M. Biochemical Markers of Renal Function. Curr. Med. Chem. 2016;23:2018–2040. doi: 10.2174/0929867323666160115130241. - DOI - PubMed
    1. Zhang W.R., Parikh C.R. Biomarkers of Acute and Chronic Kidney Disease. Annu. Rev. Physiol. 2019;81:309–333. doi: 10.1146/annurev-physiol-020518-114605. - DOI - PMC - PubMed
    1. Levey A.S. Defining AKD: The Spectrum of AKI, AKD, and CKD. Nephron. 2022;146:302–305. doi: 10.1159/000516647. - DOI - PubMed
    1. Aitekenov S., Gaipov A., Bukasov R. Review: Detection and Quantification of Proteins in Human Urine. Talanta. 2021;223:121718. doi: 10.1016/j.talanta.2020.121718. - DOI - PMC - PubMed
    1. Yu M.-C., Rich P., Foreman L., Smith J., Yu M.-S., Tanna A., Dibbur V., Unwin R., Tam F.W.K. Label Free Detection of Sensitive Mid-Infrared Biomarkers of Glomerulonephritis in Urine Using Fourier Transform Infrared Spectroscopy. Sci. Rep. 2017;7:4601. doi: 10.1038/s41598-017-04774-7. - DOI - PMC - PubMed