Effects of Translucency and Thickness of Lithium Disilicate-Reinforced Glass-Ceramic Veneers on the Degree of Conversion of a Purely Light-Curing Bonding Resin: An In Vitro Study
- PMID: 37050231
- PMCID: PMC10097364
- DOI: 10.3390/polym15071617
Effects of Translucency and Thickness of Lithium Disilicate-Reinforced Glass-Ceramic Veneers on the Degree of Conversion of a Purely Light-Curing Bonding Resin: An In Vitro Study
Abstract
The objective of this study was to evaluate the variations in the degree of conversion (DC) of a light-curing composite resin when the thickness or the translucency of lithium disilicate-enriched glass-ceramic veneers are modified. IPS e. max® CAD blocks of the MT-A2, LT-A2 and MO1 types were cut to obtain four slices with thicknesses ranging from 0.6 mm to 1 mm. A strictly light-curing composite resin (G-aenial Universal Injectable) was injected in the empty part of a silicone mold so that the veneer could then be inserted under digital pressure to the stop. A 40 s light cure (1400 mW/cm2) was then performed. Resin samples were analyzed using Fourier transform infrared (FTIR) spectroscopy. When the degree of translucency of the ceramic was modified, a decrease in the resin conversion rate was noted, but with a non-significant global p-value (p = 0.062). Interestingly, the degree of conversion of the light-curing composite resin was also modified when the ceramic's thickness increased, especially when it was over 1 mm (DC0.6 > DC0.7 > DC0.8 > DC1; p < 0.0001). This confirms that the degree of conversion of a bonding material is very dependent on the ceramic's thickness. Contradictory data are, however, found in the literature, where there are reports of an absence of a difference between the DC obtained with thicknesses of ceramics of 0.7 and 2 mm.
Keywords: FTIR spectroscopy; dental ceramics; glass-ceramics; light-curing composite resin.
Conflict of interest statement
The authors declare no conflict of interest.
References
-
- Vaicelyte A., Janssen C., Le Borgne M., Grosgogeat B. Cobalt–Chromium Dental Alloys: Metal Exposures, Toxicological Risks, CMR Classification, and EU Regulatory Framework. Crystals. 2020;10:1151. doi: 10.3390/cryst10121151. - DOI
-
- Martins F.V., Vasques W.F., Fonseca E.M. How the Variations of the Thickness in Ceramic Restorations of Lithium Disilicate and the Use of Different Photopolymerizers Influence the Degree of Conversion of the Resin Cements: A Systematic Review and Meta-Analysis. J. Prosthodont. 2019;28:e395–e403. doi: 10.1111/jopr.12920. - DOI - PubMed