. 2023 Jun;32(6):1953-1965.
doi: 10.1007/s00586-023-07674-9. Epub 2023 Apr 13.

Design and 3D printing of novel titanium spine rods with lower flexural modulus and stiffness profile with optimised imaging compatibility

Affiliations

Design and 3D printing of novel titanium spine rods with lower flexural modulus and stiffness profile with optimised imaging compatibility

Naresh Kumar et al. Eur Spine J. 2023 Jun.

Abstract

Purpose: To manufacture and test 3D printed novel design titanium spine rods with lower flexural modulus and stiffness compared to standard solid titanium rods for use in metastatic spine tumour surgery (MSTS) and osteoporosis.

Methods: Novel design titanium spine rods were designed and 3D printed. Three-point bending test was performed to assess mechanical performance of rods, while a French bender was used to assess intraoperative rod contourability. Furthermore, 3D printed spine rods were tested for CT & MR imaging compatibility using phantom setup.

Results: Different spine rod designs generated includes shell, voronoi, gyroid, diamond, weaire-phelan, kelvin, and star. Tests showed 3D printed rods had lower flexural modulus with reduction ranging from 2 to 25% versus standard rod. Shell rods exhibited highest reduction in flexural modulus of 25% (~ 77.4 GPa) and star rod exhibited lowest reduction in flexural modulus of 2% (100.8GPa). 3D printed rod showed reduction in stiffness ranging from 40 to 59%. Shell rod displayed highest reduction in stiffness of 59% (179.9 N/mm) and gyroid had least reduction in stiffness of 40% (~ 259.2 N/mm). Rod bending test showed that except gyroid, other rod designs demonstrated lesser bending difficulty versus standard rod. All 3D printed rods demonstrated improved CT/MR imaging compatibility with reduced artefacts versus standard rod.

Conclusion: By utilising novel design approach, we successfully generated a spine rod design portfolio with lower flexural modulus/stiffness profile and better CT/MR imaging compatibility for potential use in MSTS/other conditions such as osteoporosis. Thus, exploration of new rod designs in surgical application could enhance treatment outcome and improve quality of life for patients.

Keywords: 3D printing; Mechanical properties; Medical imaging; Spine rods; Surgery; Ti6Al4V.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, Bray F (2021) Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 71:209–249. https://doi.org/10.3322/caac.21660 - DOI - PubMed
    1. Kumar N, Alathur Ramakrishnan S, Lopez KG, Madhu S, Ramos MRD, Fuh JYH, Hallinan J, Nolan CP, Benneker LM, Vellayappan BA (2021) Can polyether ether ketone dethrone titanium as the choice implant material for metastatic spine tumor surgery? World Neurosurg 148:94–109. https://doi.org/10.1016/j.wneu.2021.01.059 - DOI - PubMed
    1. Wright E, Ricciardi F, Arts M, Buchowski JM, Chung CK, Coppes M, Crockard A, Depreitere B, Fehlings M, Kawahara N, Lee CS, Leung Y, Martin-Benlloch A, Massicotte E, Mazel C, Oner C, Peul W, Quraishi N, Tokuhashi Y, Tomita K, Ulbricht C, Verlaan JJ, Wang M, Choi D (2018) Metastatic spine tumor epidemiology: comparison of trends in surgery across two decades and three continents. World Neurosurg 114:e809–e817. https://doi.org/10.1016/j.wneu.2018.03.091 - DOI - PubMed
    1. Kumar N, Lopez KG, Alathur Ramakrishnan S, Hallinan J, Fuh JYH, Pandita N, Madhu S, Kumar A, Benneker LM, Vellayappan BA (2021) Evolution of materials for implants in metastatic spine disease till date—have we found an ideal material? Radiother Oncol 163:93–104. https://doi.org/10.1016/j.radonc.2021.08.007 - DOI - PubMed
    1. Ohlin A, Mattsson E, Morgelin M, Davies JR, Svensater G, Corvec S, Tengvall P, Riesbeck K (2018) Titanium granules pre-treated with hydrogen peroxide inhibit growth of bacteria associated with post-operative infections in spine surgery. Eur Spine J 27:2463–2468. https://doi.org/10.1007/s00586-018-5619-8 - DOI - PubMed

Publication types

LinkOut - more resources