Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2023 Jul;39(3):455-466.
doi: 10.1007/s11282-023-00683-w. Epub 2023 Apr 14.

Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review

Affiliations
Review

Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review

J A Costa et al. Oral Radiol. 2023 Jul.

Abstract

The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.

Keywords: Bone loss; CBCT; Cone-beam computed tomography; Dental implant; Peri-implant.

PubMed Disclaimer

Conflict of interest statement

Not applicable.

Figures

Fig. 1
Fig. 1
Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) flow diagram for the search strategy

Similar articles

Cited by

References

    1. Saberi BV, Khosravifard N, Ghandari F, Hadinezhad A. Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection. Imaging Sci Dent. 2019;49(4):265–272. doi: 10.5624/isd.2019.49.4.265. - DOI - PMC - PubMed
    1. Fienitz T, Schwarz F, Ritter L, Dreiseidler T, Becker J, Rothamel D. Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs. Clin Oral Implants Res. 2012;23(7):882–887. doi: 10.1111/j.1600-0501.2011.02232.x. - DOI - PubMed
    1. Pelekos G, Tse JMN, Ho D, Tonetti MS. Defect morphology, bone thickness, exposure settings and examiner experience affect the diagnostic accuracy of standardized digital periapical radiographic images but not of cone beam computed tomography in the detection of peri-implant osseous defects: A. J Clin Periodontol. 2019;46(12):1294–1302. doi: 10.1111/jcpe.13200. - DOI - PubMed
    1. Pelekos G, Acharya A, Tonetti MS, Bornstein MM. Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: a systematic review. Clin Oral Implants Res. 2018;29(5):443–464. doi: 10.1111/clr.13143. - DOI - PubMed
    1. Hilgenfeld T, Juerchott A, Deisenhofer UK, Krisam J, Rammelsberg P, Heiland S, et al. Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implants—an in vitro study. Clin Oral Implants Res. 2018;29(9):922–930. doi: 10.1111/clr.13348. - DOI - PubMed

Publication types

MeSH terms

LinkOut - more resources