. 2023 Oct;33(7):3159-3165.
doi: 10.1007/s00590-023-03546-6. Epub 2023 Apr 17.

Glenoid component placement accuracy in total shoulder arthroplasty with preoperative planning and standard instrumentation is not influenced by supero-inferior glenoid erosion

Affiliations

Glenoid component placement accuracy in total shoulder arthroplasty with preoperative planning and standard instrumentation is not influenced by supero-inferior glenoid erosion

David P Hagan et al. Eur J Orthop Surg Traumatol. 2023 Oct.

Abstract

Purpose: Accurate glenoid component placement in total shoulder arthroplasty (TSA) remains challenging even with preoperative planning, especially for variable glenoid erosion patterns in the coronal plane.

Methods: We retrospectively reviewed 170 primary TSAs in which preoperative planning software was used. After registration of intraoperative bony landmarks, surgeons were blinded to the navigation screen and attempted to implement their plan by simulating placement of a central-axis guide pin: 230 screenshots of simulated guide pin placement were included (aTSA = 66, rTSA = 164). Displacement, error in version and inclination, and overall malposition from the preoperatively-planned target point were stratified by the Favard classification describing superior-inferior glenoid wear: E0 (n = 89); E1 (n = 81); E2 (n = 29); E3(n = 29); E4(n = 2). Malposition was considered > 10° for version/inclination errors or > 4 mm displacement from the starting point.

Results: Mean displacement error was 3.5 ± 2.7 mm (aTSA = 2.7 ± 2.3 mm, rTSA = 3.8 ± 2.9 mm), version error was 5.7 ± 4.7° (aTSA = 5.8 ± 4.4°, rTSA = 5.7 ± 4.8°), inclination error was 7.1 ± 5.6 (aTSA = 4.8 ± 4.8°, rTSA = 8.1 ± 5.7°), and malposition rate was 53% (aTSA = 38%, rTSA = 59%). When compared by Favard classification, there were no differences in any measure; when stratified by TSA type, version error differed for rTSAs (P = .038), with E1 having the greatest version error (6.9 ± 5.2°) and E3 the least (4.2 ± 3.4°). When comparing glenoids without wear (E0) and glenoids with superior wear (E2 and E3), the only difference was greater version error in glenoids without wear (6.0 ± 4.9° vs. 4.6 ± 3.7°, P = .041).

Conclusions: Glenoid malposition did not differ based on coronal glenoid morphology. Although, malposition was relatively high, suggesting surgeons should consider alternate techniques beyond preoperative planning and standard instrumentation in TSA. LEVEL OF EVIDENCE III: Retrospective Cohort Study.

Keywords: Anatomic total shoulder arthroplasty; Reverse total shoulder arthroplasty; Shoulder arthroplasty; Shoulder replacement.

PubMed Disclaimer

References

    1. Wagner ER, Farley KX, Higgins I et al (2020) The incidence of shoulder arthroplasty: rise and future projections compared with hip and knee arthroplasty. J Shoulder Elbow Surg 29:2601–2609. https://doi.org/10.1016/j.jse.2020.03.049 - DOI - PubMed
    1. Zhang M, Junaid S, Gregory T et al (2019) Effect of baseplate positioning on fixation of reverse total shoulder arthroplasty. Clin Biomech 62:15–22. https://doi.org/10.1016/j.clinbiomech.2018.12.021 - DOI
    1. Hao KA, Sutton CD, Wright TW et al (2022) Influence of glenoid wear pattern on glenoid component placement accuracy in shoulder arthroplasty. JSES Int 6:200–208. https://doi.org/10.1016/j.jseint.2021.11.021 - DOI - PubMed - PMC
    1. Ho JC, Sabesan VJ, Iannotti JP (2013) Glenoid component retroversion is associated with osteolysis. J Bone Joint Surg-Am Vol 95(12):e82-1-8. https://doi.org/10.2106/JBJS.L.00336 - DOI
    1. Jang YH, Lee JH, Kim SH (2020) Effect of scapular notching on clinical outcomes after reverse total shoulder arthroplasty: a meta-analysis. Bone Jt J 102:1438–1445. https://doi.org/10.1302/0301-620X.102B11.BJJ-2020-0449.R1 - DOI

MeSH terms

LinkOut - more resources