Meta-Analysis
. 2023 Jun;101(7):1203-1213.
doi: 10.1002/ccd.30666. Epub 2023 Apr 18.

Computed tomography-derived membranous septum length as predictor of conduction abnormalities and permanent pacemaker implantation after TAVI: A meta-analysis of observational studies

Affiliations
Meta-Analysis

Computed tomography-derived membranous septum length as predictor of conduction abnormalities and permanent pacemaker implantation after TAVI: A meta-analysis of observational studies

Michel Pompeu Sá et al. Catheter Cardiovasc Interv. 2023 Jun.

Abstract

Background: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI.

Objectives: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI.

Methods: Study-level meta-analysis of studies published by September 30, 2022.

Results: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively.

Conclusion: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.

Keywords: aortic valve; cardiac surgical procedures; cardiovascular surgical procedures; heart valve prosthesis implantation; heart valves; meta-analysis; transcatheter aortic valve replacement.

PubMed Disclaimer

References

REFERENCES

    1. Sá MP, Jacquemyn X, Sun T, et al. Late outcomes of permanent pacemaker implantation after TAVR: meta-analysis of reconstructed time-to-event data. J Soc Cardiovasc Angiogr Interv. 2022;1(5):100434. doi:10.1016/j.jscai.2022.100434
    1. Mahajan S, Gupta R, Malik AH, et al. Predictors of permanent pacemaker insertion after TAVR: a systematic review and updated meta-analysis. J Cardiovasc Electrophysiol. 2021;32(5):1411-1420.
    1. Piazza N, Nuis RJ, Tzikas A, et al. Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation. EuroIntervention. 2010;6:475-484.
    1. Maeno Y, Abramowitz Y, Kawamori H, et al. A highly predictive risk model for pacemaker implantation after TAVR. JACC Cardiovasc Imaging. 2017;10:1139-1147.
    1. van Gils L, Wöhrle J, Hildick-Smith D, et al. Importance of contrast aortography with lotus transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2018;11:119-128.

Publication types

MeSH terms

LinkOut - more resources