Review
. 2023 Jun 1;29(3):215-222.
doi: 10.1097/MCC.0000000000001039. Epub 2023 Apr 4.

Pulse wave analysis: basic concepts and clinical application in intensive care medicine

Affiliations
Review

Pulse wave analysis: basic concepts and clinical application in intensive care medicine

Kristen K Thomsen et al. Curr Opin Crit Care. .

Abstract

Purpose of review: The measurement of cardiac output ( CO ) is important in patients with circulatory shock. Pulse wave analysis (PWA) estimates CO continuously and in real-time using the mathematical analysis of the arterial pressure waveform. We describe different PWA methods and provide a framework for CO monitoring using PWA in critically ill patients.

Recent findings: PWA monitoring systems can be classified according to their invasiveness (into invasive, minimally invasive, and noninvasive systems) and their calibration method (into externally calibrated, internally calibrated, and uncalibrated systems). PWA requires optimal arterial pressure waveform signals. Marked alterations and rapid changes in systemic vascular resistance and vasomotor tone can impair the measurement performance of PWA.

Summary: Noninvasive PWA methods are generally not recommended in critically ill patients (who have arterial catheters anyway). PWA systems can be used to continuously track stroke volume and CO in real-time during tests of fluid responsiveness or during therapeutic interventions. During fluid challenges, continuous CO monitoring is important because - if CO decreases - a fluid challenge can be stopped early to avoid further unnecessary fluid administration. PWA externally calibrated to indicator dilution methods can be used - in addition to echocardiography - to diagnose the type of shock.

PubMed Disclaimer

References

    1. Cecconi M, De Backer D, Antonelli M, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med 2014; 40:1795–1815.
    1. Saugel B, Vincent JL. Cardiac output monitoring: how to choose the optimal method for the individual patient. Curr Opin Crit Care 2018; 24:165–172.
    1. Saugel B, Vincent JL, Wagner JY. Personalized hemodynamic management. Curr Opin Crit Care 2017; 23:334–341.
    1. Rajaram SS, Desai NK, Kalra A, et al. Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev 2013; 2:CD003408.
    1. Teboul JL, Saugel B, Cecconi M, et al. Less invasive hemodynamic monitoring in critically ill patients. Intensive Care Med 2016; 42:1350–1359.