. 2024 Jun;27(2):146-153.
doi: 10.1007/s10047-023-01396-x. Epub 2023 Apr 20.

Evaluation of the reproducibility of preoperative three-dimensional computed tomography planning for posterolateral approach total hip arthroplasty

Affiliations

Evaluation of the reproducibility of preoperative three-dimensional computed tomography planning for posterolateral approach total hip arthroplasty

Takehiro Kaneoka et al. J Artif Organs. 2024 Jun.

Abstract

The anteversion of the stem is occasionally intentionally changed by the surgeon for patients with smaller femoral neck anteversion during total hip arthroplasty (THA). However, the reproducibility of preoperative planning with increasing anteversion has been rarely assessed. The present study investigated it using two types of stems. This retrospective study included patients who underwent primary posterolateral THA using taper-wedge (TS group; 73 hips) and anatomical (AS group; 70 hips) stems. Characteristics of sex and age were matched in the two groups by propensity score matching. In both groups, the relationship between the preoperative three-dimensional planning and postoperative stem position, and the relationship between postoperative stem position and femoral neck anteversion (FNA) were evaluated. In the TS group, there were no significant differences in average stem anteversion (SA) between preoperative planning and postoperative placement (36.1° ± 7.0° and 36.6° ± 11.1°, respectively: p = 0.651). The absolute error of SA was 8.1° ± 6.4°. In the AS group, the postoperative SA was significantly smaller than the preoperative planning SA (22.7° ± 11.6° and 30.0° ± 9.3°, respectively: p < 0.001). The absolute error of SA was 9.0° ± 5.8°. The postoperative SA was significantly larger than the FNA in the TS group (36.6° ± 11.1° and 26.3° ± 10.9°, respectively: p < 0.001). However, no significant differences between the two were observed in the AS group (23.7° ± 10.1° and 22.7° ± 11.6°, respectively: p = 0.253). The preoperative planning of intentional increasing anteversion did not show high reproducibility with taper-wedge and anatomical stems. The anatomical stem was placed according to the femoral medullary canal regardless of preoperative planning with increased SA.

Keywords: Anatomical stem; Anteversion; Reproducibility; Taper-wedge stem; Total hip arthroplasty.

PubMed Disclaimer

References

    1. Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty. 2005;20:427–35. - DOI - PubMed
    1. Gerhardt DM, Sanders RJ, de Visser E, van Susante JL. Excessive polyethylene wear and acetabular bone defects from standard use of a hooded acetabular insert in total hip arthroplasty. Int Orthop. 2014;38:1585–90. - PubMed - PMC
    1. Nakahara E, Uemura K, Ando W, et al. Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip. J Artif Organs. 2020;23:255–61. - DOI - PubMed
    1. Yamazaki K, Imagama T, Matsuki Y, et al. Evaluation of femoral anteversion, hip rotation, and lateral patellar tilt after total hip arthroplasty using a changeable neck system. J Artif Organs. 2021;24:492–7. - DOI - PubMed
    1. Iwana D, Nakamura N, Miki H, et al. Accuracy of angle and position of the cup using computed tomography-based navigation systems in total hip arthroplasty. Comput Aided Surg. 2013;18:187–94. - DOI - PubMed