Abstract
A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versus low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens.
Similar articles
-
Indoor air quality in two urban elementary schools--measurements of airborne fungi, carpet allergens, CO2, temperature, and relative humidity.J Occup Environ Hyg. 2005 Nov;2(11):553-66. doi: 10.1080/15459620500324453. J Occup Environ Hyg. 2005. PMID: 16223714
-
Current asthma and respiratory symptoms among pupils in Shanghai, China: influence of building ventilation, nitrogen dioxide, ozone, and formaldehyde in classrooms.Indoor Air. 2006 Dec;16(6):454-64. doi: 10.1111/j.1600-0668.2006.00439.x. Indoor Air. 2006. PMID: 17100666
-
Viruses as the causative agent related to 'dampness' and the missing link between allergen exposure and onset of allergic disease.Indoor Air. 2005 Oct;15(5):363-6. doi: 10.1111/j.1600-0668.2005.00382.x. Indoor Air. 2005. PMID: 16108909
-
[Allergic diseases in the indoor environment].Zentralbl Hyg Umweltmed. 1995 Apr;197(1-3):196-211. Zentralbl Hyg Umweltmed. 1995. PMID: 8579709 Review. German.
-
Mechanisms and characteristics of airway sensitization to indoor allergens.Monaldi Arch Chest Dis. 2001 Feb;56(1):55-63. Monaldi Arch Chest Dis. 2001. PMID: 11407212 Review.
Cited by
-
Exposure science in an age of rapidly changing climate: challenges and opportunities.J Expo Sci Environ Epidemiol. 2016 Nov;26(6):529-538. doi: 10.1038/jes.2016.35. Epub 2016 Aug 3. J Expo Sci Environ Epidemiol. 2016. PMID: 27485992 Free PMC article. Review.
-
Making the Case for "Whole System" Approaches: Integrating Public Health and Housing.Int J Environ Res Public Health. 2018 Oct 24;15(11):2345. doi: 10.3390/ijerph15112345. Int J Environ Res Public Health. 2018. PMID: 30355973 Free PMC article. Review.
-
New York State Climate Impacts Assessment Chapter 04: Buildings.Ann N Y Acad Sci. 2024 Dec;1542(1):214-252. doi: 10.1111/nyas.15200. Epub 2024 Dec 9. Ann N Y Acad Sci. 2024. PMID: 39652388 Free PMC article.
-
Low-carbon indoor humidity regulation via 3D-printed superhygroscopic building components.Nat Commun. 2025 Jan 10;16(1):425. doi: 10.1038/s41467-024-54944-1. Nat Commun. 2025. PMID: 39794308 Free PMC article.
-
Use of a robotic sampling platform to assess young children's exposure to indoor bioaerosols.Indoor Air. 2012 Apr;22(2):159-69. doi: 10.1111/j.1600-0668.2011.00749.x. Epub 2011 Oct 24. Indoor Air. 2012. PMID: 21954880 Free PMC article.
References