Structure and composition of the inner limiting membrane of the retina. SEM on frozen resin-cracked and enzyme-digested retinas of Macaca mulatta
- PMID: 3710190
- DOI: 10.1007/BF02150029
Structure and composition of the inner limiting membrane of the retina. SEM on frozen resin-cracked and enzyme-digested retinas of Macaca mulatta
Abstract
After a historical introduction describing previous observations and views on the structure and composition of the internal limiting membrane of the retina (MLI), it is concluded that no definite unifying concept exists concerning the MLI structure. The authors applied frozen resin cracking with hexamethyldisilazane (HMDS) desiccation on normal and enzyme-digested specimens of monkey retinas. Distinct differences were observed between equatorial, macular, and optic disc regions. The MLI in the equatorial and disc regions was about 70 nm thick with an outer dense, basement membranelike part and an inner, loose fibrillar meshwork fusing with the vitreous fibers. The foveal region was 400 nm thick; the dense outer layer was thicker than normal basement membrane, whereas the inner loose meshwork had only a few fibrils. The enzyme-digestion experiments showed that the fibrillar meshwork consisted mainly of collagen fibers surrounded by predominantly hyaluronic acid.
Similar articles
-
Morphology of the vitreoretinal border region.Acta Ophthalmol Scand Suppl. 1997;(222):1-31. Acta Ophthalmol Scand Suppl. 1997. PMID: 9298170
-
Structure of the vitread face of the monkey optic disc (Macaca mulatta). SEM on frozen resin-cracked optic nerveheads supplemented by TEM and immunohistochemistry.Graefes Arch Clin Exp Ophthalmol. 1988;226(4):377-83. doi: 10.1007/BF02172971. Graefes Arch Clin Exp Ophthalmol. 1988. PMID: 3049259
-
Hexamethyldisilazane in preparation of retinal tissue for scanning electron microscopy.Ophthalmic Res. 1986;18(4):203-8. doi: 10.1159/000265435. Ophthalmic Res. 1986. PMID: 3534677
-
Structure of the human vitreoretinal border region.Ophthalmologica. 1994;208(2):82-91. doi: 10.1159/000310458. Ophthalmologica. 1994. PMID: 8183530
-
The role of scanning electron microscopy in ophthalmic science.Scanning Microsc. 1988 Sep;2(3):1695-723. Scanning Microsc. 1988. PMID: 3059483 Review.
Cited by
-
Vital dyes increase the rigidity of the internal limiting membrane.Eye (Lond). 2013 Nov;27(11):1308-15. doi: 10.1038/eye.2013.178. Epub 2013 Aug 16. Eye (Lond). 2013. PMID: 23949493 Free PMC article.
-
Pre-retinal delivery of recombinant adeno-associated virus vector significantly improves retinal transduction efficiency.Mol Ther Methods Clin Dev. 2021 Jun 12;22:96-106. doi: 10.1016/j.omtm.2021.06.005. eCollection 2021 Sep 10. Mol Ther Methods Clin Dev. 2021. PMID: 34485598 Free PMC article.
-
Optical coherence tomography retinal imaging: narrative review of technological advancements and clinical applications.Ann Transl Med. 2025 Apr 30;13(2):17. doi: 10.21037/atm-24-211. Epub 2025 Apr 29. Ann Transl Med. 2025. PMID: 40438521 Free PMC article. Review.
-
Carbon nanotube electrodes for retinal implants: A study of structural and functional integration over time.Biomaterials. 2017 Jan;112:108-121. doi: 10.1016/j.biomaterials.2016.10.018. Epub 2016 Oct 11. Biomaterials. 2017. PMID: 27760395 Free PMC article.
-
Chondroitin sulfate enhances the barrier function of basement membrane assembled by heparan sulfate.Development. 2022 Jun 15;149(12):dev200569. doi: 10.1242/dev.200569. Epub 2022 Jun 16. Development. 2022. PMID: 35608020 Free PMC article.