Agreement Between Measured Weight and Fluid Balance in Mechanically Ventilated Children in Intensive Care
- PMID: 37102717
- DOI: 10.1097/PCC.0000000000003258
Agreement Between Measured Weight and Fluid Balance in Mechanically Ventilated Children in Intensive Care
Abstract
Objectives: To investigate the agreement between change in body weight (BW) and fluid balance (FB), and the precision and safety of BW measurement in mechanically ventilated infants in intensive care.
Design: Prospective observational study.
Setting: Tertiary PICU.
Patients: Infants following cardiac surgery, at baseline, 24 hours, and 48 hours.
Interventions: BW and FB measurement at three time points.
Measurements and main results: Between May 2021 and September 2022, we studied 61 children. The median age was 8 days (interquartile range [IQR], 1.0-14.0 d). The median BW at baseline was 3,518 g (IQR, 3,134-3,928 g). Change in BW was -36 g (IQR, -145 to 105 g) and -97 g (IQR, -240 to -28 g) between baseline and 24 hours, and between 24 and 48 hours, respectively. Change in FB was -82 mL (IQR, -173 to 12 mL) and -107 mL (IQR, -226 to 103) between baseline and 24 hours, and between 24 and 48 hours, respectively. In Bland-Altman analyses, the mean bias between BW and FB at 24 and 48 hours was 54 g (95% CI, 12-97) and -43 g (95% CI, -108 to 23), respectively. This exceeded 1% of the median BW, and limits of agreement ranged from 7.6% to 15% of baseline BW. The precision of paired weight measurements, performed sequentially at each time interval, was high (median difference of ≤1% of BW at each time point). The median weight of connected devices ranged from 2.7% to 3% of BW. There were no episodes of tube or device dislodgments and no change in vasoactive therapies during weight measurements.
Conclusions: There is moderate agreement between the changes in FB and BW, albeit greater than 1% of baseline BW, and the limits of this agreement are wide. Weighing mechanically ventilated infants in intensive care is a relatively safe and precise method for estimating change in fluid status. Device weight represents a relatively large proportion of BW.
Copyright © 2023 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.
Conflict of interest statement
The authors have disclosed that they do not have any potential conflicts of interest.
References
-
- Ayalon I, Woo JG, Basu RK, et al.: Weight as a risk factor for mortality in critically ill patients. Pediatrics. 2020; 146:1–10
-
- Ahearn MA, Soranno DE, Stidham T, et al.: Adherence to daily weights and total fluid orders in the pediatric intensive care unit. Pediatr Qual Saf. 2018; 3:e110
-
- Schneider AG, Thorpe C, Dellbridge K, et al.: Electronic bed weighing vs daily fluid balance changes after cardiac surgery. J Crit Care. 2013; 28:1113.e1–5
-
- Schneider AG, Baldwin I, Freitag E, et al.: Estimation of fluid status changes in critically ill patients: Fluid balance chart or electronic bed weight? J Crit Care. 2012; 27:745.e7–12
-
- You JW, Lee SJ, Kim YE, et al.: Association between weight change and clinical outcomes in critically ill patients. J Crit Care. 2013; 28:923–927
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical