Observational Study
. 2023 Apr 12;23(8):3911.
doi: 10.3390/s23083911.

Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test

Affiliations
Observational Study

Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test

Elena Bocos-Corredor et al. Sensors (Basel). .

Abstract

The aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values of ROM between different pressure levels. This was a descriptive, observational, cross-sectional, feasibility study. Participants performed a full-range craniocervical flexion and the CCFT. During the CCFT, a pressure sensor and a wireless inertial sensor simultaneously registered data of pressure and ROM. A web application was developed using HTML and NodeJS technologies. Forty-five participants successfully finished the study protocol (20 males, 25 females; 32 (11.48) years). ANOVAs showed large effect significant interactions between pressure levels and the percentage of full craniocervical flexion ROM when considering the 6 pressure reference levels of the CCFT (p < 0.001; η2 = 0.697), 11 pressure levels separated by 1 mmHg (p < 0.001; η2 = 0.683), and 21 pressure levels separated by 0.5 mmHg (p < 0.001; η2 = 0.671). The novel time synchronizing system seems a feasible option to provide real-time monitoring of both pressure and ROM, which could serve as reference targets to further investigate the potential use of inertial sensor technology to assess or train deep cervical flexors.

Keywords: assessment technology; biomechanics feasibility studies; movement disorders; neck pain.

PubMed Disclaimer

Conflict of interest statement

RR is the CEO of Werium Solutions, manufacturer of the inertial wearable sensor used in the study. The other authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Figures

Figure 1
Figure 1
(a) Relationship between % of full CCROM and pressure; (b) relationship between degrees of CCROM and pressure. Data are represented as mean ± 2 * SE. CCROM: craniocervical flexion range of motion.

Similar articles

Cited by

References

    1. Cohen S.P. Epidemiology, Diagnosis, and Treatment of Neck Pain. Mayo Clin. Proc. 2015;90:284–299. doi: 10.1016/j.mayocp.2014.09.008. - DOI - PubMed
    1. Hoy D., March L., Woolf A., Blyth F., Brooks P., Smith E., Vos T., Jan B., Blore J., Murray C., et al. The Global Burden of Neck Pain: Estimates from the Global Burden of Disease 2010 Study. Ann. Rheum. Dis. 2014;73:1309–1315. doi: 10.1136/annrheumdis-2013-204431. - DOI - PubMed
    1. Greenberg D.L. Evaluation and Treatment of Shoulder Pain. Med. Clin. North Am. 2014;98:487–504. doi: 10.1016/j.mcna.2014.01.016. - DOI - PubMed
    1. O’Leary S., Hoogma C., Solberg Ø.M., Sundberg S., Pedler A., Van Wyk L. Comparative Strength and Endurance Parameters of the Craniocervical and Cervicothoracic Extensors and Flexors in Females with and without Idiopathic Neck. J. Appl. Biomech. 2019;35:209–215. doi: 10.1123/jab.2018-0033. - DOI - PubMed
    1. Cagnie B., Cools A., De Loose V., Cambier D., Danneels L. Differences in Isometric Neck Muscle Strength between Healthy Controls and Women with Chronic Neck Pain: The Use of a Reliable Measurement. Arch. Phys. Med. Rehabil. 2007;88:1441–1445. doi: 10.1016/j.apmr.2007.06.776. - DOI - PubMed

Publication types