Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
- PMID: 37112252
- PMCID: PMC10141233
- DOI: 10.3390/s23083911
Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
Abstract
The aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values of ROM between different pressure levels. This was a descriptive, observational, cross-sectional, feasibility study. Participants performed a full-range craniocervical flexion and the CCFT. During the CCFT, a pressure sensor and a wireless inertial sensor simultaneously registered data of pressure and ROM. A web application was developed using HTML and NodeJS technologies. Forty-five participants successfully finished the study protocol (20 males, 25 females; 32 (11.48) years). ANOVAs showed large effect significant interactions between pressure levels and the percentage of full craniocervical flexion ROM when considering the 6 pressure reference levels of the CCFT (p < 0.001; η2 = 0.697), 11 pressure levels separated by 1 mmHg (p < 0.001; η2 = 0.683), and 21 pressure levels separated by 0.5 mmHg (p < 0.001; η2 = 0.671). The novel time synchronizing system seems a feasible option to provide real-time monitoring of both pressure and ROM, which could serve as reference targets to further investigate the potential use of inertial sensor technology to assess or train deep cervical flexors.
Keywords: assessment technology; biomechanics feasibility studies; movement disorders; neck pain.
Conflict of interest statement
RR is the CEO of Werium Solutions, manufacturer of the inertial wearable sensor used in the study. The other authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
Figures
Similar articles
-
Reliability and usability of a novel inertial sensor-based system to test craniocervical flexion movement control.J Neuroeng Rehabil. 2024 Sep 23;21(1):170. doi: 10.1186/s12984-024-01438-2. J Neuroeng Rehabil. 2024. PMID: 39313805 Free PMC article.
-
A novel use of inertial sensors to measure the craniocervical flexion range of motion associated to the craniocervical flexion test: an observational study.J Neuroeng Rehabil. 2020 Nov 19;17(1):152. doi: 10.1186/s12984-020-00784-1. J Neuroeng Rehabil. 2020. PMID: 33213452 Free PMC article.
-
Kinematic analysis of sensorimotor control during the craniocervical flexion movement in patients with neck pain and asymptomatic individuals: a cross-sectional study.J Neuroeng Rehabil. 2023 Jan 17;20(1):8. doi: 10.1186/s12984-023-01133-8. J Neuroeng Rehabil. 2023. PMID: 36650553 Free PMC article.
-
Clinical assessment of the deep cervical flexor muscles: the craniocervical flexion test.J Manipulative Physiol Ther. 2008 Sep;31(7):525-33. doi: 10.1016/j.jmpt.2008.08.003. J Manipulative Physiol Ther. 2008. PMID: 18804003 Review.
-
Reliability, Validity, and Responsiveness of the Craniocervical Flexion Test in People Who Are Asymptomatic and Patients With Nonspecific Neck Pain: A Systematic Review and Meta-Analysis.Phys Ther. 2022 Jul 4;102(7):pzac054. doi: 10.1093/ptj/pzac054. Phys Ther. 2022. PMID: 35554598
Cited by
-
Reliability and usability of a novel inertial sensor-based system to test craniocervical flexion movement control.J Neuroeng Rehabil. 2024 Sep 23;21(1):170. doi: 10.1186/s12984-024-01438-2. J Neuroeng Rehabil. 2024. PMID: 39313805 Free PMC article.
References
-
- O’Leary S., Hoogma C., Solberg Ø.M., Sundberg S., Pedler A., Van Wyk L. Comparative Strength and Endurance Parameters of the Craniocervical and Cervicothoracic Extensors and Flexors in Females with and without Idiopathic Neck. J. Appl. Biomech. 2019;35:209–215. doi: 10.1123/jab.2018-0033. - DOI - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical