Comparative Study
. 1986 Jun;7(6):1379-85.
doi: 10.1016/s0735-1097(86)80160-7.

Accuracy and pitfalls of Doppler evaluation of the pressure gradient in aortic coarctation

Free article
Comparative Study

Accuracy and pitfalls of Doppler evaluation of the pressure gradient in aortic coarctation

G R Marx et al. J Am Coll Cardiol. 1986 Jun.
Free article

Abstract

Although the pressure gradient in aortic coarctation can usually be obtained by comparison of upper and lower limb blood pressures measured by sphygmomanometry, some patients may have upper or lower limb arterial compromise as a result of prior procedures or anomalous origin of the subclavian arteries, either of which may preclude accurate gradient measurement. To determine whether Doppler echocardiography could predict the pressure gradient, the Doppler method was used to predict transcoarctation gradients in 35 studies and the data were compared with the gradients measured at catheterization. Jet velocities were not adequately obtained by Doppler recording in three neonates with coarctation and patent ductus arteriosus, leaving 32 studies for analysis. The mean age of the study patients was 6 +/- 5.8 years. The mean Doppler-estimated gradient, calculated using only jet velocities distal to the obstruction (V2) in the modified Bernoulli equation, was 44 +/- 17 mm Hg, and the mean catheterization gradient was 36 +/- 21 mm Hg (p = NS; r = 0.91, SEE = 7.0 mm Hg; slope = 0.75, y = 17.3 mm Hg). The mean Doppler-estimated gradient using both the pre- and postcoarctation velocities (V1 and V2) in the modified Bernoulli equation (n = 26) was 36 +/- 20 mm Hg, and the mean catheterization gradient was 36 +/- 21 mm Hg (p = NS; r = 0.98, SEE = 4.2 mm Hg; slope = 0.91, y = 2.8 mm Hg). Doppler echocardiography closely estimated the pressure gradient in aortic coarctation, and estimation of the gradient improved when the velocities proximal as well as distal to the obstruction were included in the modified Bernoulli equation.

PubMed Disclaimer