. 2023 Aug;31(8):3434-3440.
doi: 10.1007/s00167-023-07421-z. Epub 2023 Apr 28.

Smaller diameter femoral tunnel biocomposite interference screws provide adequate fixation strength in anterior cruciate ligament reconstruction

Affiliations

Smaller diameter femoral tunnel biocomposite interference screws provide adequate fixation strength in anterior cruciate ligament reconstruction

Jason G Ina et al. Knee Surg Sports Traumatol Arthrosc. 2023 Aug.

Abstract

Purpose: The purpose of this study was to evaluate the effect of bioabsorbable interference screw diameter on the pullout strength and failure mode for femoral tunnel fixation in primary anterior cruciate ligament reconstruction (ACLR) at time zero fixation using bone-patellar tendon-bone (BTB) autograft in a cadaveric model.

Methods: Twenty-four fresh-frozen cadaveric knees were obtained from 17 different donors. Specimens were allocated to three different treatment groups (n = 8 per group) based on interference screw diameter: 6 mm, 7 mm, or 8 mm biocomposite interference screw. All specimens underwent dual energy X-ray absorptiometry (DEXA) scanning prior to allocation to ensure no difference in bone mineral density among groups (n.s.). All specimens underwent femoral-sided ACLR with BTB autograft. Specimens subsequently underwent mechanical testing under monotonic loading conditions to failure. The load to failure and failure mechanism were recorded.

Results: The mean pullout force (N) at time zero for each group was 309 ± 213 N, 518 ± 313 N, and 541 ± 267 N for 6 mm, 7 mm, and 8 mm biocomposite interference screw diameter, respectively (n.s.). One specimen in the 6 mm group, two specimens in the 7 mm group, and one specimen in the 8 mm group failed by screw pullout. The remainder in each group failed by graft failure (n.s.).

Conclusion: Biocomposite interference screw diameter did not have a significant influence on fixation pullout strength or failure mode following femoral tunnel fixation using BTB autograft at time zero. A 6 mm interference screw can improve preservation of native bone stock, increase potential for biologic healing, and decrease the risk of damage to the graft during insertion without significantly compromising fixation strength. This study supports the use of smaller 6 mm interference screw diameter options for femoral tunnel fixation in ACLR.

Keywords: ACL; Allograft; Biomechanics; Knee; Ligaments.

PubMed Disclaimer

References

    1. Su CA, Knapik DM, Trivedi NN, Megerian MF, Salata MJ, Voos JE (2020) Femoral interference screw fixation in ACL reconstruction using bone-patellar tendon-bone grafts. JBJS Rev 8(1):e0066 - DOI - PubMed
    1. Dai W, Leng X, Wang J, Cheng J, Hu X, Ao Y (2022) Quadriceps tendon autograft versus bone-patellar tendon–bone and hamstring tendon autografts for anterior cruciate ligament reconstruction: a systematic review and meta-analysis. Am J Sports Med 50(12):3425–3439 - DOI - PubMed
    1. Salmon LJ, Russell VJ, Refshauge K, Kader D, Connolly C, Linklater J, Pinczewski LA (2006) Long-term outcome of endoscopic anterior cruciate ligament reconstruction with patellar tendon autograft: minimum 13-year review. Am J Sports Med 34(5):721–732 - DOI - PubMed
    1. Samuelsen BT, Webster KE, Johnson NR, Hewett TE, Krych AJ (2017) Hamstring autograft versus patellar tendon autograft for ACL reconstruction: is there a difference in graft failure rate? A meta-analysis of 47,613 patients. Clin Orthop Relat Res 475(10):2459–2468 - DOI - PubMed - PMC
    1. Kruse LM, Gray B, Wright RW (2012) Rehabilitation after anterior cruciate ligament reconstruction. J Bone Joint Surg Am 94(19):1737–1748 - DOI - PubMed - PMC

Grants and funding

LinkOut - more resources