Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct;34(10):2619-2621.
doi: 10.1007/s00192-023-05522-4. Epub 2023 May 5.

Recurrent vesico-cervical fistula: our experience

Affiliations

Recurrent vesico-cervical fistula: our experience

Arunima Saini et al. Int Urogynecol J. 2023 Oct.

Abstract

Introduction and hypothesis: Vesico-cervical (VCxF) is an uncommon entity among the gamut of genitourinary fistulas. The common causes include prolonged labor, previous lower-segment cesarean sections (LSCS), difficult vaginal deliveries, and traumatic injuries.

Methods: A 31-year-old woman presented with a history of LSCS for prolonged labor 4 years ago followed by a failed robotic repair for diagnosed VCxF and vesico-uterine fistula (VUtF) 1 year ago. The patient developed a recurrence 4 weeks after catheter removal. The patient underwent cystoscopic fulguration 6 months after the robotic surgery, but this failed after 2 weeks. Now, the patient presented with continuous urine leakage through the vagina for 6 months. On evaluation, she was diagnosed with recurrent VCxF and a repeat transabdominal repair was planned. On cystovaginoscopy, there was difficulty in negotiating the fistulous tract from either end. With great difficulty, we placed the guidewire from the vaginal end, which reached a false paracervical passage. Although in the false tract, the guidewire helped with localization of the intraoperative fistula site. After docking, port placement, and localization of the fistula site (tug on the guide wire), a mini cystostomy was performed. A plane was created between the bladder and cervicovaginal layer and dissected up to 1 cm beyond the fistula. The cervicovaginal layer was closed. An omental tissue interposition was followed by cystotomy closure and drain placement.

Results: The postoperative period was uneventful, and the patient was discharged on the 2nd day after drain removal. The catheter was removed after 3 weeks and the patient is doing fine under regular follow-up for 6 months.

Conclusions: It is challenging to diagnose and repair VCxF. Transabdominal repair is better than transvaginal repair owing to its location. Patients can opt for open or minimally invasive (laparoscopic/robotic) surgery, with better postoperative outcomes in minimally invasive techniques.

Keywords: Fistula; Robotic repair; Vesico-cervical; Vesico-uterine fistula; Vesico-vaginal.

PubMed Disclaimer

References

    1. Jóźwik M, Jóźwik M, Lotocki W. Vesicouterine fistula—an analysis of 24 cases from Poland. Int J Gynecol Obstet. 1997;57(2):169–72. - DOI
    1. Hadzi-Djokie JB, Pejeie TP. Colovic VC—vesicouterine fistula: report of 14 cases. BJU Int. 2007;100(6):1361–3. - DOI
    1. Magudapathi C, Manickam R, Thangavelu K. Vesicocervical fistula: rare complication secondary to intrauterine device (Lippes loop) erosion. Int Urogynecol J. 2015;26(6):927–9. - DOI - PubMed
    1. Kleeman SD, Vasallo B, Segal J, Karram MM. Vesicocervical fistula following insertion of a modified McDonald suture. BJOG. 2002;109(12):1408–9. - DOI - PubMed
    1. Glolomb J, Ben-Chaim J, Goldwasser B, Korach J, Mashiach S. Conservative treatment of a vesicocervical fistula resulting from Shirodkar cervical cerclage. J Urol. 1993;149:833–4. - DOI

LinkOut - more resources