Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection

Affiliations

Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection

Daniel Miles et al. J Vasc Surg Cases Innov Tech. .

Abstract

Background: Persistent distal false lumen (FL) perfusion after thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD) can lead to aneurysmal degeneration and an increased risk of rupture. We have presented our initial experience using a modified "candy-plug" (CP) technique for FL embolization.

Methods: From February 2021 to July 2022, we treated six patients using the modified CP technique. All the patients had undergone prior or simultaneous TEVAR for chronic TBAD with persistent FL perfusion and aneurysm expansion. Bilateral common femoral artery access was obtained, and intravascular ultrasound was used to confirm wire access in the true lumen (TL) and FL. A conformable TAG device (W.L. Gore & Associates, Flagstaff, AZ) was used in four cases and an Excluder aortic cuff (W.L. Gore & Associates) in two cases. The device was modified by placing a constraining "napkin-ring" suture through the middle segment of the device. Femoral sheaths were placed in the TL and FL. A standard TL TEVAR extension was performed at the level of the celiac artery (zone 5). Next, the CP device was advanced and deployed in the FL, distally aligning it with the TL device. An appropriately sized Amplatzer II plug (Abbot Vascular, Santa Clara, CA) was then deployed in the constrained segment of the modified stent graft. Completion angiography was performed to confirm successful FL embolization.

Results: Technical success was defined as successful deployment of the CP device in the FL. The technical success rate was 100% (six of six patients). Clinical success was defined as the cessation of aneurysm growth on follow-up computed tomography angiography. No 30-day mortality, myocardial infarction, stroke, spinal cord ischemia, access site complications, or aortic-related reinterventions occurred. Surveillance imaging at a mean follow-up of 10 months confirmed clinical success (stable aneurysm size or shrinkage) for all five patients with follow-up data available.

Conclusions: The modified CP embolization technique is a promising solution for persistent distal FL perfusion after TEVAR for TBAD. Further investigation is required to determine the long-term durability of this technique as an adjunct to TEVAR to promote aortic remodeling.

Keywords: Aortic remodeling; Candy-plug; False lumen embolization; False lumen perfusion; TEVAR; Type B aortic dissection.

PubMed Disclaimer

Figures

Fig 1
Fig 1
Diagram of the modified candy-plug (CP) technique.
Fig 2
Fig 2
Back table modification of false lumen (FL) stent graft with Gore-Tex CV-2 suture.
Fig 3
Fig 3
Napkin-ring narrowing of false lumen (FL) stent graft.
Fig 4
Fig 4
Computed tomography angiography image of modified candy-plug (CP) device demonstrating false lumen (FL) thrombosis and no entry flow.

References

    1. Mani K., Clough R.E., Lyons O.T., Bell R.E., Carrell T.W., Zayed H.A., et al. Predictors of outcome after endovascular repair for chronic type B dissection. Eur J Vasc Endovasc Surg. 2012;43:386–391. - PubMed
    1. Kölbel T., Lohrenz C., Kieback A., Diener H., Debus E.S., Larena-Avellaneda A. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther. 2013;20:484–489. - PubMed
    1. Furukawa T., Uchida N., Yamane Y., Yamada K. A pitfall of false lumen embolization in chronic aortic dissection: intimal injury caused by the embolization device edge. Interact Cardiovasc Thorac Surg. 2017;24:153–155. - PubMed
    1. Ogawa Y., Nishimaki H., Chiba K., Murakami K., Sakurai Y., Fujiwara K., et al. Candy-plug technique using an Excluder aortic extender for distal occlusion of a large false lumen aneurysm in chronic aortic dissection. J Endovasc Ther. 2016;23:483–486. - PubMed
    1. Kotani S., Inoue Y., Kasai M., Suzuki S., Hachiya T. Modified “candy-plug” technique for chronic type B aortic dissection with aneurysmal dilatation: a case report. J Cardiothorac Surg. 2017;12:77. - PMC - PubMed

LinkOut - more resources