. 2023 Sep;90(3):839-851.
doi: 10.1002/mrm.29688. Epub 2023 May 8.

Adaptive model-based Magnetic Resonance

Affiliations

Adaptive model-based Magnetic Resonance

Inbal Beracha et al. Magn Reson Med. 2023 Sep.

Abstract

Purpose: Conventional sequences are static in nature, fixing measurement parameters in advance in anticipation of a wide range of expected tissue parameter values. We set out to design and benchmark a new, personalized approach-termed adaptive MR-in which incoming subject data is used to update and fine-tune the pulse sequence parameters in real time.

Methods: We implemented an adaptive, real-time multi-echo (MTE) experiment for estimating T2 s. Our approach combined a Bayesian framework with model-based reconstruction. It maintained and continuously updated a prior distribution of the desired tissue parameters, including T2 , which was used to guide the selection of sequence parameters in real time.

Results: Computer simulations predicted accelerations between 1.7- and 3.3-fold for adaptive multi-echo sequences relative to static ones. These predictions were corroborated in phantom experiments. In healthy volunteers, our adaptive framework accelerated the measurement of T2 for n-acetyl-aspartate by a factor of 2.5.

Conclusion: Adaptive pulse sequences that alter their excitations in real time could provide substantial reductions in acquisition times. Given the generality of our proposed framework, our results motivate further research into other adaptive model-based approaches to MRI and MRS.

Keywords: Bayesian estimation; adaptive MR; model-based reconstruction; qMRI; quantitative MR; real-time MRI.

PubMed Disclaimer

References

REFERENCES

    1. Merritt ME, Harrison C, Storey C, Jeffrey FM, Sherry AD, Malloy CR. Hyperpolarized 13C allows a direct measure of flux through a single enzyme-catalyzed step by NMR. Proc Natl Acad Sci U S A. 2007;104:19773-19777.
    1. Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature. 1973;242:190-191.
    1. Ackerman JJH, Grove TH, Wong GG, Gadian DG, Radda GK. Mapping of metabolites in whole animals by 31P NMR using surface coils. Nature. 1980;283:167-170.
    1. Wüthrich K. NMR studies of structure and function of biological macromolecules (Nobel lecture). Angew Chem Int Ed Engl. 2003;42:3340-3363.
    1. Mehta BB, Coppo S, McGivney DF, et al. Magnetic resonance fingerprinting: a technical review. Magn Reson Med. 2019;81:25-46.

Publication types

LinkOut - more resources