Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns
- PMID: 37158489
- PMCID: PMC10167941
- DOI: 10.1002/14651858.CD012660.pub2
Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns
Abstract
Background: Jaundice is a very common condition in newborns, affecting up to 60% of term newborns and 80% of preterm newborns in the first week of life. Jaundice is caused by increased bilirubin in the blood from the breakdown of red blood cells. The gold standard for measuring bilirubin levels is obtaining a blood sample and processing it in a laboratory. However, noninvasive transcutaneous bilirubin (TcB) measurement devices are widely available and used in many settings to estimate total serum bilirubin (TSB) levels.
Objectives: To determine the diagnostic accuracy of transcutaneous bilirubin measurement for detecting hyperbilirubinaemia in newborns.
Search methods: We searched CENTRAL, MEDLINE, Embase, CINAHL and trial registries up to 18 August 2022. We also checked the reference lists of all included studies and relevant systematic reviews for other potentially eligible studies.
Selection criteria: We included cross-sectional and prospective cohort studies that evaluated the accuracy of any TcB device compared to TSB measurement in term or preterm newborn infants (0 to 28 days postnatal age). All included studies provided sufficient data and information to create a 2 × 2 table for the calculation of measures of diagnostic accuracy, including sensitivities and specificities. We excluded studies that only reported correlation coefficients.
Data collection and analysis: Two review authors independently applied the eligibility criteria to all citations from the search and extracted data from the included studies using a standard data extraction form. We summarised the available results narratively and, where possible, we combined study data in a meta-analysis.
Main results: We included 23 studies, involving 5058 participants. All studies had low risk of bias as measured by the QUADAS 2 tool. The studies were conducted in different countries and settings, included newborns of different gestational and postnatal ages, compared various TcB devices (including the JM 101, JM 102, JM 103, BiliChek, Bilitest and JH20-1C) and used different cutoff values for a positive result. In most studies, the TcB measurement was taken from the forehead, sternum, or both. The sensitivity of various TcB cutoff values to detect significant hyperbilirubinaemia ranged from 74% to 100%, and specificity ranged from 18% to 89%.
Authors' conclusions: The high sensitivity of TcB to detect hyperbilirubinaemia suggests that TcB devices are reliable screening tests for ruling out hyperbilirubinaemia in newborn infants. Positive test results would require confirmation through serum bilirubin measurement.
Copyright © 2023 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
Conflict of interest statement
AO: none known CO: none known OU: none known KG has declared he has no conflict of interest; but he is an Editor with Cochrane Neonatal Group. He was not be involved in the editorial process of this manuscript. JS: none known CW: none know VB: none known MF is an Information Specialist and Managing Editor with the Cochrane Neonatal Group. She was not involved in the editorial process of this manuscript.
Figures






















Update of
- doi: 10.1002/14651858.CD012660
References
References to studies included in this review
Bental 2009 {published data only}
Bertini 2008 {published data only}
Bhutta 1991 {published data only}
-
- Bhutta ZA, Yusuf K. Transcutaneous bilirubinometry in Pakistani newborns: a preliminary report. Journal of the Pakistan Medical Association 1991;41(7):155-6. [PMID: ] - PubMed
Bilgen 1998 {published data only}
Boo 2007 {published data only}
Campbell 2011 {published data only}
Christo 1988 {published data only}
-
- Christo GG, Kamath S, Aroor AR, Venkatesh A. Transcutaneous bilirubinometry in newborns. Indian Pediatrics 1988;25(11):1073-7. [PMID: ] - PubMed
Ercan 2018 {published data only}
-
- Ercan Ş, Özgün G. The accuracy of transcutaneous bilirubinometer measurements to identify the hyperbilirubinemia in outpatient newborn population. Clinical biochemistry 2018;55:69-74. [PMID: ] - PubMed
Hemmati 2013 {published data only}
Karon 2008 {published data only}
Karrar 1989 {published data only}
Kitsommart 2013 {published data only}
Knupfer 2001 {published data only}
-
- Knupfer M, Pulzer F, Braun L, Heilmann A, Robel-Tillig E, Vogtmann C. Transcutaneous bilirubinometry in preterm infants. Acta Paediatrica 2001;90(8):899-903. [PMID: ] - PubMed
Kolman 2007 {published data only}
Lam 2008 {published data only}
-
- Lam TS, Tsui KL, Kam CW. Evaluation of a point-of-care transcutaneous bilirubinometer in Chinese neonates at an accident and emergency department. Hong Kong Medical Journal 2008;14(5):356-60. [PMID: ] - PubMed
Maisels 1982 {published data only}
-
- Maisels MJ, Conrad S. Transcutaneous bilirubin measurements in full-term infants. Pediatrics 1982;70(3):464-7. [PMID: ] - PubMed
Mendoza‐Chuctaya 2021 {published data only}
-
- Mendoza-Chuctaya G, Ramos-Chuctaya KR, Maraza-Aquino EJ, Ruiz-Esquivel JE, Velazquez-Cordova LAS. Accuracy of transcutaneous bilirubin measurement in full-term newborns at 3400 meters above sea level. Boletin medico del Hospital Infantil de Mexico 2021;78(2):116-22. [PMID: ] - PubMed
Neocleous 2014 {published data only}
Samanta 2004 {published data only}
Schumacher 1985 {published data only}
-
- Schumacher RE, Thornbery JM, Gutcher GR. Transcutaneous bilirubinometry: a comparison of old and new methods. Pediatrics 1985;76(1):10-4. [PMID: ] - PubMed
Taha 1984 {published data only}
Wong 2002 {published data only}
References to studies excluded from this review
Adriaansen 2020 {published data only}
-
- Adriaansen M, Williams S, den Boom J. Evaluation of two transcutaneous bilirubin devices for the assessment of neonatal jaundice in a diverse New Zealand population. New Zealand Journal of Medical Laboratory Science 2020;74(1):11-16.
Afanetti 2014 {published data only}
Agrawal 2019 {published data only}
-
- Agrawal G, Garg K, Sitaraman S, Sarna A. Comparison of diagnostic accuracy of different sites for transcutaneous bilirubin measurement in early preterm infants. Indian Journal of Pediatrics 2019;86(1):32-7. [PMID: ] - PubMed
Ahmed 2010 {published data only}
Ahn 2003 {published data only}
Akahira‐Azuma 2013 {published data only}
Alsaedi 2016 {published data only}
Alsaedi 2018 {published data only}
Amato 1985 {published data only}
-
- Amato M, Pasquier S, Muralt G. Transcutaneous bilirubin determination: correlation in white premature infants weighing less than 1500 gm. Schweizerische Medizinische Wochenschrift 1985;115(27-28):937-8. [PMID: ] - PubMed
Amato 1990 {published data only}
Arman 2020 {published data only}
-
- Arman D, Topcuoglu S, Gursoy T, Ovali F, Karatekin G. The accuracy of transcutaneous bilirubinometry in preterm infants. Journal of Perinatology 2020;40(2):212-8. [PMID: ] - PubMed
Babaei 2012 {published data only}
-
- Babaei H, Alipour A, Sheikhi S. Comparison of transcutaneous and serum bilirubin level in term neonates with jaundice. Scientific Journal of Kurdistan University of Medical 2012;17(4):10-16.
Badiee 2012 {published data only}
Beck 2003 {published data only}
Berget 1984 {published data only}
-
- Berget M, Finne PH. Transcutaneous bilirubinometry in newborn infants. Tidsskrift for den Norske Laegeforening 1984;104(14):984-6. [PMID: ] - PubMed
Bhat 1987 {published data only}
-
- Bhat V, Srinivasan S, Usha TS, Puri RK. Correlation of transcutaneous bilirubinometry with serum bilirubin in south Indian neonates. Indian Journal of Medical Research 1987;86:49-52. [PMID: ] - PubMed
Bhutani 2000 {published data only}
Boo 1984 {published data only}
-
- Boo NY, Bakar AA. Transcutaneous bilirubinometry in Malay, Chinese and Indian term neonates. Medical Journal of Malaysia 1984;39(1):35-7. [PMID: ] - PubMed
Bosschaart 2012 {published data only}
-
- Bosschaart N, Kok JH, Newsum AM, Ouweneel DM, Mentink R, Leeuwen TG, et al. Limitations and opportunities of transcutaneous bilirubin measurements. Pediatrics 2012;129(4):689-94. [PMID: ] - PubMed
Bourchier 1987 {published data only}
-
- Bourchier D, Cull AB, Oettli PE. Transcutaneous bilirubinometry: 22 months experience at Waikato Women's Hospital. New Zealand Medical Journal 1987;100(832):599-600. [PMID: ] - PubMed
Briscoe 2002 {published data only}
Carbonell 1999 {published data only}
-
- Carbonell Estrany X, Botet Mussons F, Figueras Aloy J, Riu Godo A. Hyperbilirubinemia in full-term newborns. Predictive factors. Anales Espanoles de Pediatria 1999;50(4):389-92. [PMID: ] - PubMed
Carbonell 2001 {published data only}
Carceller 2006 {published data only}
-
- Carceller AM, Delvin E, Gonthier M, Gregoire MC, Cousineau J, Alexandrov L. Evaluation of transcutaneous bilirubin measurement and agreement with bilirubinemia. Annales de Biologie Clinique 2006;64(6):575-9. [PMID: ] - PubMed
Casnocha 2021 {published data only}
Castro 2019 {published data only}
-
- Castro A, Zozaya C, Cuesta MT, Gonzalez M, Villar G, Alcaraz A. Usefulness of transcutaneous bilirubin assessment measured in non-photo-exposed skin to guide the length of phototherapy: an observational study. Journal of Perinatal Medicine 2019;47(5):568-73. [PMID: ] - PubMed
Cat 2021 {published data only}
Chang 2006 {published data only}
-
- Chang YH, Hsieh WS, Chou HC, Chen CY, Wu JY, Tsao PN. The effectiveness of a noninvasive transcutaneous bilirubin meter in reducing the need for blood sampling in Taiwanese neonates. Clinical Neonatology 2006;13(2):60-3. [DOI: 10.7098/CN.200612.0060] - DOI
Chawla 2014 {published data only}
Chimhini 2018 {published data only}
Chokemungmeepisarn 2020 {published data only}
-
- Chokemungmeepisarn P, Tantiprabha W, Kosarat S, Manopunya S. Accuracy of the Bilicare transcutaneous bilirubinometer as the predischarge screening tool for significant hyperbilirubinemia in healthy term and late preterm neonates. Journal of Maternal-fetal & Neonatal Medicine 2020;33(1):57-61. [PMID: ] - PubMed
Conceicao 2014 {published data only}
Dagli 2018 {published data only}
-
- Dagli P, Vasava S. Accuracy of transcutaneous bilirubinometry in neonates receiving phototherapy. Journal of Nepal Paediatric Society 2018;38(1):1-7.
Dai 1996 {published data only}
De Luca 2007 {published data only}
De Luca 2008b {published data only}
-
- De Luca D, Zecca E, Corsello M, Tiberi E, Semeraro C, Romagnoli C. Attempt to improve transcutaneous bilirubinometry: a double-blind study of Medick BiliMed versus Respironics BiliCheck. Archives of Disease in Childhood. Fetal and Neonatal Edition 2008;93(2):F135-9. [DOI: 10.1136/adc.2007.121053] [PMID: ] - DOI - PubMed
Dianova 2021 {published data only}
-
- Dianova E, Fogel J, Verma R. Predictability of transcutaneous bilirubinometry in late preterm and term infants at risk for pathological hyperbilirubinemia. Journal of Neonatal Perinatal Medicine 2021;14(2):261-7. - PubMed
Dominguez 1993 {published data only}
-
- Dominguez Ortega F, Ormazabal Ramos JC, Martin Zarza M, Domenech Martinez E. Transcutaneous bilirubinometry: correlation of the reading site obtained with spectrophotometry and diazo reaction technique. Anales Espanoles de Pediatria 1993;39(5):438-40. [PMID: ] - PubMed
Donzelli 2000 {published data only}
Ebbesen 2002 {published data only}
Ebbesen 2012 {published data only}
El‐Kabbany 2017 {published data only}
-
- El-Kabbany ZA, Toaima NN, Shedid AM. Implementation and validating transcutaneous bilirubinometry for neonates. Egyptian Pediatric Association Gazette 2017;65(2):38-42.
Engle 2002 {published data only}
Engle 2005 {published data only}
Fabris 1984 {published data only}
-
- Fabris C, Licata D, Roberi P, Miglio C, Garzena E, Cavo L, et al. Evaluation of transcutaneous bilirubinometry in newborn infants. Minerva Pediatrica 1984;36(11):565-70. [PMID: ] - PubMed
Faridi 1998 {published data only}
-
- Faridi MM. Transcutaneous bilirubinometry in neonates. Indian Pediatrics 1998;35(6):568-9. [PMID: ] - PubMed
Felc 2005 {published data only}
-
- Felc Z. Improvement of conventional transcutaneous bilirubinometry results in term newborn infants. American journal of perinatology 2005;22(4):173-9. [PMID: ] - PubMed
Fisher 2015 {published data only}
-
- Fisher BG, Lakshman R. Transcutaneous bilirubin measurement in neonates with jaundice requiring phototherapy. Archives of Disease in Childhood 2015;100(Suppl 3):A139.
Foged 1983 {published data only}
-
- Foged N, Kristensen GB, Kamper J. Transcutaneous bilirubinometry. A non-invasive method of measuring physiological jaundice. Ugeskrift for Laeger 1983;145(38):2935-7. [PMID: ] - PubMed
Fok 1986 {published data only}
Fonseca 2012 {published data only}
Goldman 1982 {published data only}
Gondale 2013 {published data only}
-
- Gondale G, Taksande A, Vilhekar K. Assessment of a transcutaneous bilirubinometer in the evaluation of neonatal Hyperbilirubinemia in hospitalized neonates. American Journal of Advances in Medical Science 2013;1(2):7-12.
Gothwal 2021 {published data only}
-
- Gothwal S, Singh N, Sitaraman S, Choudhary R, Meena KK, Bairwa GS, et al. Efficacy of transcutaneous bilirubinometry as compared to serum bilirubin in preterm newborn during phototherapy. European Journal of Pediatrics 2021;180(8):2629-36. [PMID: ] - PubMed
Grabenhenrich 2014 {published data only}
Greco 2017 {published data only}
-
- Greco C, Iskander IF, Akmal DM, El Houchi SZ, Khairy DA, Bedogni G, et al. Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns. Journal of Perinatology 2017;37(9):1028-31. [PMID: ] - PubMed
Gunaseelan 2017 {published data only}
-
- Gunaseelan Sushil, Devadas Sahana, Pai Nandita. Correlation of transcutaneous bilirubin and serum bilirubin concentration in term and late preterm newborns. Journal of Clinical Neonatology 2017;6(3):154-8.
Harish 1998 {published data only}
-
- Harish R, Sharma DB. Transcutaneous bilirubinometry in neonates: evaluation of Minolta Air shields jaundicemeter. Indian Pediatrics 1998;35(3):264-7. [PMID: ] - PubMed
Hasani 2019 {published data only}
-
- Hasani M, Ghiasi A, Kheirkhah M, Sabuteh M, Karimian Z, Zaheri H, et al. Predictive value of transcutaneous bilirubinometry on third day of birth in diagnosis of hyperbilirubinemia in term and near-term neonates. Koomesh 2019;21(1):19-24.
Hegyi 1981 {published data only}
Heick 1982 {published data only}
-
- Heick C, Mieth D, Fallenstein F, Schubiger G, Nars PW, Amato M. Transcutaneous bilirubin determination in the newborn infant. Recommendations of the Swiss Neonatology Group. Helvetica Paediatrica Acta 1982;37(6):589-97. [PMID: ] - PubMed
Hemmati 2021 {published data only}
-
- Hemmati F, Hashemi Z, Yazdani N. Comparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates. Tehran University Medical Journal 2021;78(12):835-842.
Hill 2016 {published data only}
-
- Hill S, Yamamoto L, Simons J, Jameson M, Field J, Antwi-Boasiako E. Can transcutaneous bilirubin measurement safely replace plasma bilirubin in well newborns greater than 35 weeks gestation? Clinical Biochemistry 2016;49(18):1434-5.
Ho 2006 {published data only}
-
- Ho EY, Lee SY, Chow CB, Chung JW. BiliCheck transcutaneous bilirubinometer: a screening tool for neonatal jaundice in the Chinese population [Xianggang yi xue za zhi]. Hong Kong Medical Journal 2006;12(2):99-102. [PMID: ] - PubMed
Ho 2006a {published data only}
Holland 2009 {published data only}
Hoppenot 2012 {published data only}
Hulzebos 2019 {published data only}
Itoh 2001 {published data only}
Jahadi 2013 {published data only}
-
- Jahadi R, Sajjadian N. Trans cutaneous bilirubinometry for preterm. Intensive Care Medicine 2013;39:S144-S145.
Jalalodini 2019 {published data only}
-
- Jalalodini A, Ghaljaei F. Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in term neonates with hyperbilirubinemia: a descriptive-analytical study. Journal of Comprehensive Pediatrics 2019;10(4):10(4):e84720.
Jangaard 2006 {published data only}
Janjindamai 2005 {published data only}
-
- Janjindamai W, Tansantiwong T. Accuracy of transcutaneous bilirubinometer estimates using BiliCheck in Thai neonates [Chotmaihet Thangphaet]. Journal of the Medical Association of Thailand 2005;88(2):187-90. [PMID: ] - PubMed
Jegathesan 2017 {published data only}
-
- Jegathesan T, Campbell D, Debono M, Shah V, Twiss J, Sgro M. Investigating the accuracy of an upgraded transcutaneous bilirubin screening tool by site of testing. Paediatrics & Child Health 2017;22(Suppl 1):e41.
Jegathesan 2021 {published data only}
-
- Jegathesan T, Campbell DM, Ray JG, Shah V, Berger H, Hayeems RZ, et al. Transcutaneous versus total serum bilirubin measurements in preterm Infants. Neonatology 2021;118(4):443-53. - PubMed
Jeon 2020 {published data only}
Jnah 2018 {published data only}
-
- Jnah A, Newberry DM, Eisenbeisz E. Comparison of transcutaneous and serum bilirubin measurements in neonates 30 to 34 weeks' gestation before, during, and after phototherapy. Advances in Neonatal Care 2018;18(2):144-53. [PMID: ] - PubMed
Johnson 2020 {published data only}
-
- Johnson SM, Vasu V, Marseille C, Hill C, Janvier L, Toussaint P, et al. Validation of transcutaneous bilirubinometry during phototherapy for detection and monitoring of neonatal jaundice in a low-income setting. Paediatrics and International Child Health 2020;40(1):25-9. [PMID: ] - PubMed
Jones 2017 {published data only}
-
- Jones DF, McRea AR, Knowles JD, Lin FC, Burnette E, Reller LA, et al. A prospective comparison of transcutaneous and serum bilirubin within brief time intervals. Clinical Pediatrics 2017;56(11):1013-7. [PMID: ] - PubMed
Joseph 2014 {published data only}
-
- Joseph R, Chinnadurai A, Yeo W, Nkouibert P, George M, Chan, E. Reducing serum bilirubin determinations in outpatient newborns by screening with transcutaneous bilirubinometry. Archives of Disease in Childhood 2014;99:A459-A460.
Juster‐Reicher 2014 {published data only}
-
- Juster-Reicher A, Flidel-Rimon O, Rozin I, Shinwell ES. Correlation of transcutaneous bilirubinometry (TcB) and total serum bilirubin (TsB) levels after phototherapy. Journal of Maternal-Fetal & Neonatal Medicine 2014;88(2):1-3. [PMID: ] - PubMed
Karen 2009 {published data only}
Karolyi 2004 {published data only}
Kaynak‐Turkmen 2011 {published data only}
-
- Kaynak-Turkmen M, Aydogdu SA, Gokbulut C, Yenisey C, Soz O, Cetinkaya-Cakmak B. Transcutaneous measurement of bilirubin in Turkish newborns: comparison with total serum bilirubin. Turkish Journal of Pediatrics 2011;53(1):67-74. [PMID: ] - PubMed
Kazmierczak 2004 {published data only}
Keshini 2018 {published data only}
-
- Keshini N, John S, Srinivas B. The accuracy of transcutaneous bilirubin measurement in preterm neonates. Journal of Paediatrics and Child Health 2018;54(S1):84.
Keshishian 1994 {published data only}
-
- Keshishian ES, Ovanesov EN, Prishchepa MI. Use of the method of transcutaneous bilirubinometry in hyperbilirubinemia in the newborn. Klinicheskaia Laboratornaia Diagnostika 1994;5(5):17-20. [PMID: ] - PubMed
Khajehei 2021 {published data only}
-
- Khajehei M, Chua SC, Gidaszewski B, Swain J. Comparing JM-105 and MBJ-20 transcutaneous bilirubinometers according to the area tested in ethnically diverse late-preterm and term neonates. Journal of Perinatal & Neonatal Nursing 2021;35(3):E30-7. [PMID: ] - PubMed
Knudsen 1996 {published data only}
Konana 2021 {published data only}
-
- Konana OS, Bahr TM, Strike HR, Coleman J, Snow GL, Christensen RD. Decision accuracy and safety of transcutaneous bilirubin screening at Intermountain Healthcare. Journal of Pediatrics 2021;228:53-7. [PMID: ] - PubMed
Kosarat 2013 {published data only}
-
- Kosarat S, Khuwuthyakorn V. Accuracy of transcutaneous bilirubin measurement in term newborns [Chotmaihet Thangphaet]. Journal of the Medical Association of Thailand 2013;96(2):172-7. [PMID: ] - PubMed
Kumar 1994 {published data only}
-
- Kumar A, Faridi MM, Singh N, Ahmad SH. Transcutaneous bilirubinometry in the management of bilirubinemia in term neonates. Indian Journal of Medical Research 1994;99:227-30. [PMID: ] - PubMed
Kumar 2017 {published data only}
-
- Kumar V, Kahlon P, Singh P, Singh K, Sharma A. Utility of transcutaneous bilirubinometer in tertiary care hospital. Journal of Nepal Paediatric Society 2017;37(1):72-78.
Kumar 2020 {published data only}
Kumra 2017 {published data only}
-
- Kumra T, Weaver SSJ, Prather K, Garnepudi L Bartlett EL, Crocetti M. Correlation of transcutaneous and serum bilirubin measurements in the outpatient setting. Clinical Pediatrics 2017;57(2):231-4. - PubMed
Laeeq 1993 {published data only}
-
- Laeeq A, Yasin M, Chaudhry AR. Transcutaneous bilirubinometry: clinical application. Journal of the Pakistan Medical Association 1993;43(2):28-30. [PMID: ] - PubMed
Lebrun 1982 {published data only}
-
- Lebrun F, Sender A, Goujard J, Francoual C, Amiel-Tison C. Clinical evaluation of transcutaneous bilirubinometry. Annales de Pediatrie 1982;29(7):494-8. [PMID: ] - PubMed
Leite 2007 {published data only}
Lin 1993 {published data only}
-
- Lin YJ, Ju SH, Lin CH. The clinical application of transcutaneous bilirubinometry in full-term Chinese infants. Zhonghua Min Guo Xiao Er Ke Yi Xue Hui Za Zhi 1993;34(2):69-76. [PMID: ] - PubMed
López‐Garrido 2015 {published data only}
-
- López-Garrido E, Chávez-Gutiérrez CA, Rivera-Vázquez P. Transcutaneous and serum bilirubin metering correlation in newborns at term and late preterm. Revista Mexicana de Pediatria 2015;82(5):159-64.
Mahajan 2005 {published data only}
-
- Mahajan G, Kaushal RK, Sankhyan N, Sharma RL, Nakra M. Transcutaneous bilirubinometer in assessment of neonatal jaundice in northern India. Indian Pediatrics 2005;42(1):41-5. [PMID: ] - PubMed
Mahram 2015 {published data only}
-
- Mahram M, Oveisi S, Jaberi N. Trans-cutaneous bilirubinometery versus serum bilirubin in neonatal jaundice. Acta Medica Iranica 2015;53(12):764-9. [PMID: ] - PubMed
Maisels 2004 {published data only}
Maisels 2006 {published data only}
Maisels 2011 {published data only}
Marco 2009 {published data only}
Maya‐Enero 2021 {published data only}
-
- Maya-Enero S, Candel-Pau J, Garcia-Garcia J, Duran-Jorda X. Reliability of transcutaneous bilirubin determination based on skin color determined by a neonatal skin color scale of our own. European Journal of Pediatrics 2021;180(2):607-16. [PMID: ] - PubMed
Mercanti 2007 {published data only}
Mohamed 2022 {published data only}
Moscicka 1994 {published data only}
-
- Moscicka A, Gadzinowski J, Moscicki A, Breborowicz GH, Opala T. Usefulness of transcutaneous measurements of bilirubin in infants with jaundice. Ginekologia Polska 1994;65(6):271-5. [PMID: ] - PubMed
Murli 2017 {published data only}
-
- Murli L, Thukral A, Sankar MJ, Vishnubhatla S, Deorari AK, Paul VK, et al. Reliability of transcutaneous bilirubinometry from shielded skin in neonates receiving phototherapy: a prospective cohort study. Journal of Perinatology 2017;37(2):182-7. [PMID: ] - PubMed
Nahar 2017 {published data only}
-
- Nahar N, Mannan MA, Dey AC, Ahmed F, Khan KA, Jahan I, et al. Comparison of serum bilirubin with transcutaneous bilirubinometry in late preterm and term newborn. Mymensingh Medical Journal 2017;26(3):621-7. [PMID: ] - PubMed
Namba 2007 {published data only}
Nanjundaswamy 2004 {published data only}
Nanjundaswamy 2005 {published data only}
Narang 1983 {published data only}
-
- Narang A, Buche VB. Evaluation of the Minolta Jaundice Meter as a screening device in Indian babies: a preliminary communication. Indian Pediatrics 1983;20(8):583-5. [PMID: ] - PubMed
Ochoa 2000 {published data only}
-
- Ochoa Sangrador C, Marugan Isabel VM, Tesoro Gonzalez R, Garcia Rivera MT, Hernandez Calvo MT. Evaluation of a transcutaneous bilirubinometer [Evaluacion de un instrumento de medicion de la bilirrubina transcutanea]. Anales Espanoles de Pediatria 2000;52(6):561-8. [PMID: ] - PubMed
Oyapero 2017 {published data only}
-
- Oyapero Oyejoke, Njokanma O, Disu E. Evaluation of transcutaneous bilirubinometry in term neonates at Lagos State University Teaching Hospital, Ikeja, Lagos. Journal of Clinical Neonatology 2017;6(4):213-9.
Pallas 1993 {published data only}
-
- Pallas Alonso C, Martin Puerto MJ, Mendoza Soto A, Bustos Lozano G, Flores Anton B, Orbea Gallardo C. Transcutaneous bilirubin measurement in neonates. Anales Espanoles de Pediatria 1993;38(1):33-7. [PMID: ] - PubMed
Palmer 1982 {published data only}
-
- Palmer DC, Zenner EM, Drew JH. Transcutaneous bilirubinometry: use in Australia. Australian Paediatric Journal 1982;18(4):273-6. [PMID: ] - PubMed
Panburana 2010 {published data only}
-
- Panburana J, Boonkasidach S, Rearkyai S. Accuracy of transcutaneous bilirubinometry compare to total serum bilirubin measurement [Chotmaihet Thangphaet]. Journal of the Medical Association of Thailand 2010;93 Suppl 2:S81-6. [PMID: ] - PubMed
Pendse 2017 {published data only}
-
- Pendse A, Jasani B, Nanavati R, Kabra N. Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy. Indian Pediatrics 2017;54(8):641-3. [PMID: ] - PubMed
Poland 2004 {published data only}
Povaluk 2011 {published data only}
-
- Povaluk P, Shwetz E, Kliemann R. Comparative study between plasma and transcutaneous bilirubin measurements in newborns. Revista Paulista de Pediatria 2011;29(1):1-12.
Pratesi 2016 {published data only}
-
- Pratesi S, Boni L, Tofani L, Berti E, Sollai S, Dani C. Comparison of the transcutaneous bilirubinometers BiliCare and Minolta JM-103 in late preterm and term neonates. Journal of Maternal-fetal & Neonatal Medicine 2016;29(18):3014-8. [PMID: ] - PubMed
Qandalji 2012 {published data only}
-
- Qandalji BR. 1329 Comparison of transcutaneous bilirubinometer with serum bilirubin in neonates. Archives of Disease in Childhood 2012;97(Suppl 2):A378.
Qualter 2011 {published data only}
Quist 2016 {published data only}
-
- Quist FK, Bapat R, Kuch-Kunich HK, Ezeanolue K, Keeni S, Thomas R, et al. Clinical utility of transcutaneous bilirubinometer (TcB) in very low birth weight (VLBW) infants. Journal of Perinatal Medicine 2016;44(8):933-9. [PMID: ] - PubMed
Raba 2020 {published data only}
Radfar 2016 {published data only}
-
- Radfar M, Hashemieh M, Shirvani F, Madani R. Transcutaneous bilirubinometry in preterm and term newborn infants before and during phototherapy. Archives of Iranian Medicine 2016;19(5):323-8. [PMID: ] - PubMed
Raimondi 2012 {published data only}
Reyes 2008 {published data only}
-
- Reyes CA, Stednitz DR, Hahn C, Mutchie KD, McCullough SR, Kronberg K. Evaluation of the BiliChek being used on hyperbilirubinemic newborns undergoing home phototherapy. Archives of Pathology & Laboratory Medicine 2008;132(4):684-9. [DOI: 10.1043/1543-2165(2008)132[684:EOTBBU]2.0.CO;2] [PMID: ] - PubMed
Robertson 2002 {published data only}
-
- Robertson A, Kazmierczak S, Vos P. Improved transcutaneous bilirubinometry: comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population. Journal of Perinatology 2002;22(1):12-4. [DOI: 10.1038/sj.jp.7210592] [PMID: ] - DOI - PubMed
Rodriguez‐Capote 2009 {published data only}
-
- Rodriguez-Capote K, Kim K, Paes B, Turner D, Grey V. Clinical implication of the difference between transcutaneous bilirubinometry and total serum bilirubin for the classification of newborns at risk of hyperbilirubinemia. Clinical Biochemistry 2009;42(3):176-9. [DOI: 10.1016/j.clinbiochem.2008.09.108] [PMID: ] - DOI - PubMed
Rohsiswatmo 2018 {published data only}
Romagnoli 2012 {published data only}
Romagnoli 2013 {published data only}
Romo‐Pinales 1984 {published data only}
-
- Romo-Pinales J, Orozco-Gutiérrez A, Udaeta-Mora E, Graham-Pontones S. Preliminary study in Mexico on the use of the transcutaneous bilirubinometer [Estudio preliminar en Mexico sobre la utilizacion del bilirrubinometro transcutaneo]. Boletin Medico del Hospital Infantil de Mexico 1984;41(10):536-8. [PMID: ] - PubMed
Roy 2010 {published data only}
-
- Roy B, Coakley J, Badawi N. Is there a place for transcutaneous bilirubinometery in the NICU? Journal of Paediatrics and Child Health 2010;46:36.
Rubaltelli 2001 {published data only}
Rubio 2017 {published data only}
-
- Rubio A, Epiard C, Gebus M, Deiber M, Samperiz S, Genty C, et al. Diagnosis accuracy of transcutaneous bilirubinometry in very preterm newborns. Neonatology 2017;111(1):1-7. [PMID: ] - PubMed
Rush 2011 {published data only}
-
- Rush M, Wiley C. Performance evaluation of the Minolta/Drager JM-103 jaundice meter. Clinical Chemistry 2011;57(10):A52.
Rylance 2014 {published data only}
Sajjadian 2012 {published data only}
-
- Sajjadian N, Shajari H, Saalehi Z, Esphahani F, Alizadeh Taheri P. Transcutaneous bilirubin measurement in preterm neonates. Acta Medica Iranica 2012;50(11):765-70. [PMID: ] - PubMed
Samiee‐Zafarghandy 2014 {published data only}
-
- Samiee-Zafarghandy S, Feberova J, Williams K, Yasseen AS, Perkins SL, Lemyre B. Influence of skin colour on diagnostic accuracy of the jaundice meter JM 103 in newborns. Archives of Disease in Childhood. Fetal and Neonatal Edition 2014;99(6):F480-4. [DOI: 10.1136/archdischild-2013-305699] [PMID: ] - DOI - PubMed
Sanpavat 2004 {published data only}
-
- Sanpavat S, Nuchprayoon I. Noninvasive transcutaneous bilirubin as a screening test to identify the need for serum bilirubin assessment. Journal of the Medical Association of Thailand 2004;87(10):1193-8. [PMID: ] - PubMed
Sanpavat 2005 {published data only}
-
- Sanpavat S, Nuchprayoon I. Comparison of two transcutaneous bilirubinometers – Minolta AirShields Jaundice Meter JM103 and Spectrx Bilicheck--in Thai neonates. Southeast Asian Journal of Tropical Medicine and Public Health 2005;36(6):1533-7. [PMID: ] - PubMed
Sanpavat 2007 {published data only}
-
- Sanpavat S, Nuchprayoon I. Transcutaneous bilirubin in the pre-term infants. Journal of the Medical Association of Thailand [Chotmaihet Thangphaet] 2007;90(9):1803-8. [PMID: ] - PubMed
Sardar 2021 {published data only}
-
- Sardar S, Sarkar N, Ghosh M, Pal S. An observational prospective study to compare transcutaneous bilirubin with serum bilirubin in preterm newborn requiring phototherapy. Journal of Clinical Neonatology 2021;10(2):59-67.
Sarici 2014 {published data only}
Schmidt 2009 {published data only}
Sellitto 2010 {published data only}
-
- Sellitto M, De Rosa M, Internicola M, Pisanti R, Del Buono D, Iovino A et al. Measuring transcutaneous bilirubin: a comparative analysis of three devices. Journal of Maternal-Fetal and Neonatal Medicine 2010;23:560-1.
Sharma 1988 {published data only}
-
- Sharma JN, Singh RN, Lodha A, Singh J. Transcutaneous bilirubinometry in newborns. Indian Pediatrics 1988;25(8):757-60. [PMID: ] - PubMed
Sheridan‐Pereira 1982 {published data only}
Shihadeh 2016 {published data only}
-
- Shihadeh M, Kheyami D, Al Jufairi M, Jaradat A, Ansari E. Transcutaneous bilirubin measurement correlation with total serum bilirubin in healthy newborns. Bahrain Medical Bulletin 2016;38(4):208-210.
Siu 2010 {published data only}
-
- Siu LY, Siu LW, Au SK, LI KW, Tsui TK, Chang YY, et al. Evaluation of a transcutaneous bilirubinometer with two optical paths in Chinese preterm infants. Hong Kong Journal of Paediatrics 2010;15(2):132-40.
Slusher 2004 {published data only}
Soffer 2018 {published data only}
-
- Soffer OD, Barran D, Roth P. Transcutaneous bilirubin on premature neonates, can we rely on it? Pediatrics 2018;141:567.
Spence 2016 {published data only}
-
- Spence J, Bevan C, Walton E. G236(P) Introduction of a transcutaneous bilirubinometer into children's ED – a good initiative? Archives of Disease in Childhood 2016;101(Suppl 1):A129.
Srinivas 2016 {published data only}
-
- Srinivas GL, Cuff CD, Ebeling MD, Mcelligott JT. Transcutaneous bilirubinometry is a reliably conservative method of assessing neonatal jaundice. Journal of Maternal-Fetal & Neonatal Medicine 2016;29(16):2635-9. [PMID: ] - PubMed
Stillova 2007 {published data only}
-
- Stillova L, Matasova K, Mikitova T, Stilla J, Kolarovszka H, Zibolen M. Evaluation of transcutaneous bilirubinometry in preterm infants of gestational age 32-34 weeks. Biomedical Papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2007;151(2):267-71. [DOI: 10.5507/bp.2007.045] [PMID: ] - DOI - PubMed
Stillova 2009 {published data only}
Suckling 1995 {published data only}
Szabo 2004a {published data only}
Szabo 2004b {published data only}
-
- Szabo P, Wolf M, Bucher HU, Haensse D, Fauchere JC, Arlettaz R. Assessment of jaundice in preterm neonates: comparison between clinical assessment, two transcutaneous bilirubinometers and serum bilirubin values. Acta Paediatrica 2004;93(11):1491-5. [DOI: 10.1080/08035250410018328] [PMID: ] - DOI - PubMed
Tan 1982 {published data only}
Tan 1985 {published data only}
-
- Tan KL. Transcutaneous bilirubinometry in Chinese and Malay neonates. Annals of the Academy of Medicine, Singapore 1985;14(4):591-4. [PMID: ] - PubMed
Tan 1988 {published data only}
-
- Tan KL, Mylvaganam A. Transcutaneous bilirubinometry in preterm very low birthweight infants. Acta paediatrica Scandinavica 1988;77(6):796-801. [PMID: ] - PubMed
Tan 1996 {published data only}
Tan 2003 {published data only}
-
- Tan KL, Dong F. Transcutaneous bilirubinometry during and after phototherapy. Acta Paediatrica 2003;92(3):327-31. [PMID: ] - PubMed
Tayaba 1998 {published data only}
Taylor 2015 {published data only}
Teran 2011 {published data only}
Timalsina 2017 {published data only}
-
- Timalsina S, Shrestha S. Utility and accuracy of transcutaneous bilirubin as a screening test to identify the need for serum bilirubin assessment in neonates in Nepal. Clinical Chemistry 2017;63 2017;63:(Supplement 1):S259-60.
Vocel 1985 {published data only}
-
- Vocel J, Mrastikova H, Reitschlagerova V. Transcutaneous bilirubinometry using the Minolta/Air-schield in neonates. Ceskoslovenska Pediatrie 1985;40(11):649-51. [PMID: ] - PubMed
Vocel 1987 {published data only}
-
- Vocel J, Jezkova Z, Reitschlagerova V. Transcutaneous bilirubinometry using the Minolta/Air-Shields apparatus in neonates with a low birthweight. Ceskoslovenska pediatrie 1987;42(1):20-2. - PubMed
Vocel 1988 {published data only}
-
- Vocel J, Petrova L, Concha Gonzales J, Paulova M, Reitschlagerova V. Transcutaneous bilirubinometry in neonates with hyperbilirubinemia treated with phototherapy. Ceskoslovenska Pediatrie 1988;43(12):742-3. [PMID: ] - PubMed
Wainer 2009 {published data only}
Weber 2021 {published data only}
Wickremasinghe 2011 {published data only}
Willems 2004 {published data only}
-
- Willems WA, den Berg LM, Wit H, Molendijk A. Transcutaneous bilirubinometry with the Bilicheck in very premature newborns. Journal of Maternal-Fetal & Neonatal Medicine 2004;16(4):209-14. [PMID: ] - PubMed
Willemsen 2007 {published data only}
-
- Willemsen MJ, Korver CR. Transcutaneous bilirubinometry useful in the determination of hyperbilirubinaemia in icteric neonates. Nederlands Tijdschrift voor Geneeskunde 2007;151(6):359-63. [PMID: ] - PubMed
Williams 2011 {published data only}
-
- Williams C, Holland L, Blick K. Transcutaneous bilirubin comparison studies: BiliChek versus drager methods. Clinical Chemistry 2011;57(10):A137.
Yamanouchi 1980 {published data only}
-
- Yamanouchi I, Yamauchi Y, Igarashi I. Transcutaneous bilirubinometry: preliminary studies of noninvasive transcutaneous bilirubin meter in the Okayama National Hospital. Pediatrics 1980;65(2):195-202. [PMID: ] - PubMed
Yamauchi 1988 {published data only}
Yamauchi 1989a {published data only}
Yamauchi 1989b {published data only}
Yamauchi 1989c {published data only}
Yamauchi 1990 {published data only}
Yamauchi 1991 {published data only}
Yang 2019 {published data only}
Yap 2002 {published data only}
Yasuda 2003 {published data only}
Ying 2020 {published data only}
Zecca 2009 {published data only}
Zhan 2016 {published data only}
-
- Zhan C, Pan J, Du J, Yu Y, Zheng J, Chen L. Evaluation of the Bilichek transcutaneous bilirubinometer in the Chinese new-borns. Biomedical Research 2016;27(4):1390-1394.
Additional references
AAP 2004
Akman 2000
-
- Akman I, Arika Ç, Bilgen H, Kalaça S, Özek E. Transcutaneous measurement of bilirubin by icterometer during phototherapy on a bilibed. Turkish Journal of Medical Sciences 2000;32(2):165-8.
Barrington 2007
-
- Barrington KJ, Sankaran K, Canadian Paediatric Society, Fetus and Newborn Committee. Guidelines for detection, management and prevention of hyperbilirubinemia in term and late preterm newborn infants. Paediatric Child Health 2007;12(Suppl B):1B-12B.
Bhutani 2010
Burke 2009
Covidence [Computer program]
-
- Covidence. Melbourne, Australia: Veritas Health Innovation, Accessed August 2022. Available at covidence.org.
CPS 2007
-
- Barrington KJ, Sankaran K. Canadian Paediatric Society, Fetus and Newborn Committee Guidelines for detection, management and prevention of hyperbilirubinemia in term and late preterm newborn infants (35 or more weeks’ gestation). www.cps.ca/en/documents/position/hyperbilirubinemia-newborn (accessed October 3, 2018).
Dai 1997
De Luca 2008a
-
- De Luca D, Zecca E, Zuppa AA, Romagnoli C. The joint use of human and electronic eye: visual assessment of jaundice and transcutaneous bilirubinometry. Turkish Journal of Pediatrics 2008;50(5):456-61. [PMID: ] - PubMed
Ebbesen 2005
el‐Beshbishi 2009
Grohmann 2006
Harrison 1989
-
- Harrison SP, Barlow IM. Three direct spectrophotometric methods for determination of total bilirubin in neonatal and adult serum, adapted to the Technicon RA-1000 analyzer. Clinical Chemistry 1989;35(9):1980-6. [PMID: ] - PubMed
Higgins 2012
-
- Higgins T, Eckfeldt JH, Barton JC, Doumas BT. Hemoglobin, iron and bilirubin. In: Burtis CA, Ashwood ER, Bruns DE, editors(s). Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 4th edition. Missouri: Elsevier Saunders, 2012:985-1030.
Hynes 2020
-
- Hynes S, Moore Z, Patton D, O'Connor T, Nugent L. Accuracy of transcutaneous bilirubin versus serum bilirubin measurement in preterm infants receiving phototherapy: a systematic review. Advances in Neonatal Care 2020;20(6):E118-26. [PMID: ] - PubMed
Johnson 2002
Kazmierczak 2002
-
- Kazmierczak SC, Robertson AF, Catrou PG, Briley KP, Kreamer BL, Gourley GR. Direct spectrophotometric method for measurement of bilirubin in newborns: comparison with HPLC and an automated diazo method. Clinical Chemistry 2002;48(7):1096-7. [PMID: ] - PubMed
Kazmierczak 2006
-
- Kazmierczak S, Bhutani VK, Gourley G, Kerr S, Lo S, Roberston A, et al. Transcutaneous Bilirubin Testing. Laboratory Medicine Practice Guidelines: Evidence-based Practice for Point-of-care Testing. Washington (DC): National Academy of Clinical Biochemistry (NACB), 2006.
Kemper 2022
-
- Kemper AR, Newman TB, Slaughter JL, Maisels MJ, Watchko JF, Downs SM, et al. Clinical practice guideline revision: management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. Pediatrics 2022;150(3):e2022058859. - PubMed
Keren 2005
Knüpfer 2001
-
- Knüpfer M, Pulzer F, Braun L, Heilmann A, Robel-Tillig E, Vogtmann C. Transcutaneous bilirubinometry in preterm infants. Acta Paediatrica 2001;90(8):899-903. [PMID: ] - PubMed
Lauer 2011
Lo 2011
Macaskill 2010
-
- Macaskill P, Gatsonis C, Deeks JJ, Harbord RM, Takwoingi Y. Chapter 10: Analysing and presenting results. In: Deeks JJ, Bossuyt PM, Gatsonis C (editors), Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy Version 1.0. The Cochrane Collaboration, 2010. Available from: methods.cochrane.org/sdt/handbook-dta-reviews.
Madsen 2000
Maisels 1997
Mannig 2007
Moey 2016
-
- Moey PK. Transcutaneous bilirubin measurement to estimate serum bilirubin in neonates in a multi-ethnic cohort: a literature review. Proceedings of Singapore Healthcare 2016;26(1):42-57. [DOI: 10.1177/2010105816665854] - DOI
Nagar 2013
Nagar 2016
Nair 2003
Owa 2009
Srgo 2006
Wainer 2012
Whiting 2011
References to other published versions of this review
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources