Improving the interpretation of electronic fetal monitoring: the fetal reserve index
- PMID: 37164491
- DOI: 10.1016/j.ajog.2022.11.1275
Improving the interpretation of electronic fetal monitoring: the fetal reserve index
Abstract
Electronic fetal monitoring, particularly in the form of cardiotocography, forms the centerpiece of labor management. Initially successfully designed for stillbirth prevention, there was hope to also include prediction and prevention of fetal acidosis and its sequelae. With the routine use of electronic fetal monitoring, the cesarean delivery rate increased from <5% in the 1970s to >30% at present. Most at-risk cases produced healthy babies, resulting in part from considerable confusion as to the differences between diagnostic and screening tests. Electronic fetal monitoring is clearly a screening test. Multiple attempts have aimed at enhancing its ability to accurately distinguish babies at risk of in utero injury from those who are not and to do this in a timely manner so that appropriate intervention can be performed. Even key electronic fetal monitoring opinion leaders admit that this goal has yet to be achieved. Our group has developed a modified approach called the "Fetal Reserve Index" that contextualizes the findings of electronic fetal monitoring by formally including the presence of maternal, fetal, and obstetrical risk factors and increased uterine contraction frequencies and breaking up the tracing into 4 quantifiable components (heart rate, variability, decelerations, and accelerations). The result is a quantitative 8-point metric, with each variable being weighted equally in version 1.0. In multiple previously published refereed papers, we have shown that in head-to-head studies comparing the fetal reserve index with the American College of Obstetricians and Gynecologists' fetal heart rate categories, the fetal reserve index more accurately identifies babies born with cerebral palsy and could also reduce the rates of emergency cesarean delivery and vaginal operative deliveries. We found that the fetal reserve index scores and fetal pH and base excess actually begin to fall earlier in the first stage of labor than was commonly appreciated, and the fetal reserve index provides a good surrogate for pH and base excess values. Finally, the last fetal reserve index score before delivery combined with early analysis of neonatal heart rate and acid/base balance shows that the period of risk for neonatal neurologic impairment can continue for the first 30 minutes of life and requires much closer neonatal observation than is currently being done.
Keywords: acidosis; augmented electronic fetal monitoring; base excess; cardiotocography; category system; cerebral palsy; electronic fetal monitoring; fetal reserve index; fetal scalp; keeping labor safe; pH; risk factors; sampling.
Copyright © 2022 Elsevier Inc. All rights reserved.
Similar articles
-
Combined prenatal and postnatal prediction of early neonatal compromise risk.J Matern Fetal Neonatal Med. 2021 Sep;34(18):2996-3007. doi: 10.1080/14767058.2019.1676714. Epub 2019 Oct 24. J Matern Fetal Neonatal Med. 2021. PMID: 31581872
-
Safely lowering the emergency Cesarean and operative vaginal delivery rates using the Fetal Reserve Index.J Matern Fetal Neonatal Med. 2020 May;33(9):1473-1479. doi: 10.1080/14767058.2018.1519799. Epub 2018 Oct 1. J Matern Fetal Neonatal Med. 2020. PMID: 30269624
-
Reframing antepartum and intrapartum surveillance.Best Pract Res Clin Obstet Gynaecol. 2024 Dec;97:102538. doi: 10.1016/j.bpobgyn.2024.102538. Epub 2024 Sep 10. Best Pract Res Clin Obstet Gynaecol. 2024. PMID: 39500683 Review.
-
The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia.Am J Obstet Gynecol. 2017 Feb;216(2):163.e1-163.e6. doi: 10.1016/j.ajog.2016.10.009. Epub 2016 Oct 14. Am J Obstet Gynecol. 2017. PMID: 27751795
-
Evolving Frameworks for the Foundation and Practice of Electronic Fetal Monitoring.Matern Fetal Med. 2022 Apr 26;4(2):141-151. doi: 10.1097/FM9.0000000000000148. eCollection 2022 Apr. Matern Fetal Med. 2022. PMID: 40406445 Free PMC article. Review.
Cited by
-
The effect of continuous electronic fetal monitoring on mode of delivery and neonatal outcome among low-risk laboring mothers at Debre Markos comprehensive specialized hospital, Northwest Ethiopia.Front Glob Womens Health. 2024 Jun 24;5:1385343. doi: 10.3389/fgwh.2024.1385343. eCollection 2024. Front Glob Womens Health. 2024. PMID: 38979032 Free PMC article.
-
Reconceptualizing Intrauterine Resuscitation and Its Short-Term Impact.Diagnostics (Basel). 2025 Jan 23;15(3):255. doi: 10.3390/diagnostics15030255. Diagnostics (Basel). 2025. PMID: 39941185 Free PMC article.
-
Detecting and responding to deterioration of a baby during labour: surveys of maternity professionals to inform co-design and implementation of a new standardised approach.BMJ Open. 2025 Mar 6;15(3):e084578. doi: 10.1136/bmjopen-2024-084578. BMJ Open. 2025. PMID: 40050068 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical