Clockwise torque results in higher reoperation rates in left-sided femur fractures
- PMID: 37164900
- DOI: 10.1016/j.injury.2023.04.044
Clockwise torque results in higher reoperation rates in left-sided femur fractures
Abstract
Purpose: Effects of clockwise torque rotation onto proximal femoral fracture fixation have been subject of ongoing debate: fixated right-sided trochanteric fractures seem more rotationally stable than left-sided fractures in the biomechanical setting, but this theoretical advantage has not been demonstrated in the clinical setting to date. The purpose of this study was to identify a difference in early reoperation rate between patients undergoing surgery for left- versus right-sided proximal femur fractures using cephalomedullary nailing (CMN).
Materials and methods: The American College of Surgeons National Surgical Quality Improvement Program was queried from 2016-2019 to identify patients aged 50 years and older undergoing CMN for a proximal femoral fracture. The primary outcome was any unplanned reoperation within 30 days following surgery. The difference was calculated using a Chi-square test, and observed power calculated using post-hoc power analysis.
Results: In total, of 20,122 patients undergoing CMN for proximal femoral fracture management, 1.8% (n=371) had to undergo an unplanned reoperation within 30 days after surgery. Overall, 208 (2.0%) were left-sided and 163 (1.7%) right-sided fractures (p=0.052, risk ratio [RR] 1.22, 95% confidence interval [CI] 1.00-1.50), odds ratio [OR] 1.23 (95%CI 1.00-1.51), power 49.2% (α=0.05).
Conclusion: This study shows a higher risk of reoperation for left-sided compared to right-sided proximal femur fractures after CMN in a large sample size. Although results may be underpowered and statistically insignificant, this finding might substantiate the hypothesis that clockwise rotation during implant insertion and (postoperative) weightbearing may lead to higher reoperation rates.
Level of evidence: Therapeutic level II.
Keywords: Clockwise rotation; Implant surgery; Proximal femoral fracture; Reoperation rates.
Copyright © 2023. Published by Elsevier Ltd.
Conflict of interest statement
Declaration of Competing Interest Each author certifies that he or she has no commercial associations (e.g., consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article. One of the authors (JO) certifies that she received, an amount less than USD 10,000 from the Marti-Keuning-Eckhardt Foundation.