Pancreatic Juice Cytology Evaluations Using Synthetic Secretin and Serial Pancreatic Juice Aspiration Cytological Examination for the Diagnosis of Pancreatic Ductal Adenocarcinoma
- PMID: 37174928
- PMCID: PMC10177452
- DOI: 10.3390/diagnostics13091536
Pancreatic Juice Cytology Evaluations Using Synthetic Secretin and Serial Pancreatic Juice Aspiration Cytological Examination for the Diagnosis of Pancreatic Ductal Adenocarcinoma
Abstract
Pathological examination by endoscopic ultrasound-fine needle aspiration is not possible in approximately 10% of pancreatic tumor cases. Pancreatic juice cytology (PJC) is considered an alternative diagnostic method. However, its diagnostic capability is insufficient, and PJC has been repeatedly redevised. Serial pancreatic juice aspiration cytological examination (SPACE) and secretin-loaded PJC (S-PJC) have been recently introduced as alternative diagnostic methods. This study aimed to determine the diagnostic capacity and safety of SPACE and S-PJC using a propensity score-matched analysis. The sensitivity, specificity, and accuracy were 75.0%, 100%, and 92.3% for S-PJC, respectively, and 71.4%, 100%, and 92.3% for SPACE, respectively, meaning that there was no significant difference between the groups. Four patients (15.4%) each in the S-PJC and SPACE groups experienced complications, including postendoscopic retrograde cholangiopancreatography, pancreatitis, and cholangitis. Overall, there was no difference in efficacy and safety between the SPACE and S-PJC groups.
Keywords: pancreatic ductal adenocarcinoma; pancreatic juice cytology; serial pancreatic juice aspiration cytological examination; synthetic secretin.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
References
-
- Facciorusso A., Stasi E., Di Maso M., Serviddio G., Ali Hussein M.S., Muscatiello N. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis. United Eur. Gastroenterol. J. 2017;5:846–853. doi: 10.1177/2050640616680972. - DOI - PMC - PubMed
-
- Gkolfakis P., Crinò S.F., Tziatzios G., Ramai D., Papaefthymiou A., Papanikolaou I.S., Triantafyllou K., Arvanitakis M., Lisotti A., Fusaroli P., et al. Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: A network meta-analysis. Gastrointest. Endosc. 2022;95:1067–1077.e15. doi: 10.1016/j.gie.2022.01.019. - DOI - PubMed
LinkOut - more resources
Full Text Sources