Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May 4;11(5):123.
doi: 10.3390/dj11050123.

Accuracy of Zygomatic Implant Placement Using a Full Digital Planning and Custom-Made Bone-Supported Guide: A Retrospective Observational Cohort Study

Affiliations

Accuracy of Zygomatic Implant Placement Using a Full Digital Planning and Custom-Made Bone-Supported Guide: A Retrospective Observational Cohort Study

Francesco Gallo et al. Dent J (Basel). .

Abstract

The aim of the study was to evaluate the accuracy of zygomatic implant placement using customized bone-supported laser-sintered titanium templates. Pre-surgical computed tomography (CT) scans allowed to develop the ideal virtual planning for each patient. Direct metal laser-sintering was used to create the surgical guides for the implant placement. Post-operative CT scans were taken 6 months after surgery to assess any differences between the planned and placed zygomatic implants. Qualitative and quantitative three-dimensional analyses were performed with the software Slicer3D, recording linear and angular displacements after the surface registration of the planned and placed models of each implant. A total of 59 zygomatic implants were analyzed. Apical displacement showed a mean movement of 0.57 ± 0.49 mm on the X-axis, 1.1 ± 0.6 mm on the Y-axis, and 1.15 ± 0.69 mm on the Z-axis for the anterior implant, with a linear displacement of 0.51 ± 0.51 mm on the X-axis, 1.48 ± 0.9 mm on the Y-axis, and 1.34 ± 0.9 mm on the Z-axis for the posterior implant. The basal displacement showed a mean movement of 0.33 ± 0.25 mm on the X-axis, 0.66 ± 0.47 mm on the Y-axis, and 0.58 ± 0.4 mm on the Z-axis for the anterior implant, with a linear displacement of 0.39 ± 0.43 mm on the X-axis, 0.42 ± 0.35 mm on the Y-axis, and 0.66 ± 0.4 mm on the Z-axis for the posterior implant. The angular displacements recorded significative differences between the anterior implants (yaw: 0.56 ± 0.46°; pitch: 0.52 ± 0.45°; roll: 0.57 ± 0.44°) and posterior implants (yaw: 1.3 ± 0.8°; pitch: 1.3 ± 0.78°; roll: 1.28 ± 1.1°) (p < 0.05). Fully guided surgery showed good accuracy for zygomatic implant placement and it should be considered in the decision-making process.

Keywords: accuracy; computer-assisted surgery; data; denture; guided zygomatic implant surgery; implant-supported; maxillary atrophy; zygomatic implants.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Pre-operative digital planning using the EZplan Real Guide software (Noris Medical Ltd., Nesher, Israel).
Figure 2
Figure 2
(A) Full thickness flap and fixation of EZgoma® guide; (B) Implant site preparation with dedicated drills for the zygomatic fixture; (C) The zygomatic implant was screwed in place by a dedicated mounter.
Figure 3
Figure 3
Measurement of deviation between planned and placed implants.
Figure 4
Figure 4
Automated colormaps generated by the software. Different visualizations were recorded: anterior view; posterior view; implant base; implant apex.

References

    1. Block M.S., Emery R.W. Static or Dynamic Navigation for Implant Placement—Choosing the Method of Guidance. J. Oral Maxillofac. Surg. 2016;74:269–277. doi: 10.1016/j.joms.2015.09.022. - DOI - PubMed
    1. Geng W., Liu C., Su Y., Li J., Zhou Y. Accuracy of different types of computer-aided design/ computer-aided manufacturing surgical guides for dental implant placement. Int. J. Clin. Exp. Med. 2015;8:8442–8449. - PMC - PubMed
    1. Varga E., Jr., Antal M., Major L., Kiscsatári R., Braunitzer G., Piffkó J. Guidance means accuracy: A randomized clinical trial on freehand versus guided dental implantation. Clin. Oral Implant. Res. 2020;31:417–430. doi: 10.1111/clr.13578. - DOI - PubMed
    1. Besimo C.E., Lambrecht J.T., Guindy J.S. Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. Dentomaxillofacial Radiol. 2000;29:46–51. doi: 10.1038/sj.dmfr.4600491. - DOI - PubMed
    1. Colombo M., Mangano C., Mijiritsky E., Krebs M., Hauschild U., Fortin T. Clinical applications and effectiveness of guided implant surgery: A critical review based on randomized controlled trials. BMC Oral Health. 2017;17:150. doi: 10.1186/s12903-017-0441-y. - DOI - PMC - PubMed

LinkOut - more resources