Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Apr 23;11(5):1252.
doi: 10.3390/biomedicines11051252.

Correlation of Shear Bond Strength and Degree of Conversion in Conventional and Self-Adhesive Systems Used in Orthodontic Bonding Procedures

Affiliations

Correlation of Shear Bond Strength and Degree of Conversion in Conventional and Self-Adhesive Systems Used in Orthodontic Bonding Procedures

Vjera Perković et al. Biomedicines. .

Abstract

(1) Background: Self-adhesive systems have been proposed for the orthodontic bonding with the intention to reduce the traditional three-component system. (2) Methods: The sample consisted of 32 extracted intact permanent premolars randomly divided into two groups (n = 16). In Group I the metal brackets were bonded with Transbond XT Primer and Transbond XT Paste. In Group II the metal brackets were bonded with GC Ortho connect. The resin was polymerized for 20 s from two directions (mesial and occlusal) using a Bluephase light-curing unit. The shear bond strength (SBS) was measured using a universal testing machine. Immediately after SBS testing, Raman microspectrometry was performed for each sample to calculate the degree of conversion (DC). (3) Results: There was no statistically significant difference in the SBS between the two groups. A significantly higher DC (p < 0.001) value was recorded in Group II, in which the brackets were bonded with GC. Very weak or no correlation (0.01) was recorded between SBS and DC in Group I and moderate positive correlation was recorded in Group II (0.33). (4) Conclusions: No difference was found in SBS between the conventional and two-step systems used in orthodontics. The two-step system demonstrated higher DC compared to the conventional system. There is a very weak or moderate correlation between DC and SBS.

Keywords: adhesive dentistry; degree of conversion; shear bond strength.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
SBS testing with stationary magnifier.
Figure 2
Figure 2
Raman spectra for polymerized and unpolymerized GC Ortho Connect. Green line represents experimental data acquired from Raman microspectrometry; Red line represents three bell-shaped functions; Yellow line represents fitting curve; Gray line represents deselected data.

Similar articles

Cited by

References

    1. Aguirre M.J., King G.J., Waldron J.M. Assessment of bracket placement and bond strength when comparing direct bonding to indirect bonding techniques. Am. J. Orthod. 1982;82:269–276. doi: 10.1016/0002-9416(82)90461-4. - DOI - PubMed
    1. Thiyagarajah S., Spary D.J., Rock W.P. A clinical comparison of bracket bond failures in association with direct and indirect bonding. J. Orthod. 2006;33:198–204. doi: 10.1179/146531205225021615. - DOI - PubMed
    1. Read M.J.F., O’Brien K.D. A clinical trial of an indirect bonding technique with a visible light-cured adhesive. Am. J. Orthod. Dentofac. Orthop. 1990;98:259–262. doi: 10.1016/S0889-5406(05)81603-8. - DOI - PubMed
    1. Newman George V Epoxy adhesives for orthodontic attachments: Progress report. Am. J. Orthod. 1965;51:901–912. doi: 10.1016/0002-9416(65)90203-4. - DOI - PubMed
    1. Costa A.R., Correr A.B., Puppin-Rontani R.M., Vedovello S.A., Valdrighi H.C., Correr-Sobrinho L., Vedovello Filho M. Effect of bonding material, etching time and silane on the bond strength of metallic orthodontic brackets to ceramic. Braz. Dent. J. 2012;23:223–227. doi: 10.1590/S0103-64402012000300007. - DOI - PubMed

LinkOut - more resources