Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul 15:199:44-49.
doi: 10.1016/j.amjcard.2023.05.001. Epub 2023 May 26.

Pulmonary Capillary Recruitment Is Attenuated Post Left Ventricular Assist Device Implantation

Affiliations

Pulmonary Capillary Recruitment Is Attenuated Post Left Ventricular Assist Device Implantation

Chul-Ho Kim et al. Am J Cardiol. .

Abstract

There is limited knowledge of pulmonary physiology and pulmonary function after continuous flow-left ventricular assist device (CF-LVAD) implantation. Therefore, this study investigated whether CF-LVAD influenced pulmonary circulation by assessing pulmonary capillary blood volume and alveolar-capillary conductance in addition to pulmonary function in patients with heart failure. Seventeen patients with severe heart failure who were scheduled for CF-LVAD implantation (HeartMate II, III, Abbott, Abbott Park, IL or Heart Ware, Medtronic, Minneapolis, MN) participated in the study. They underwent pulmonary function testing (measures of lung volumes and flow rates) and unique measures of pulmonary physiology using a rebreathe technique that quantified the diffusing capacity of the lungs for carbon monoxide (DLCO) and diffusing capacity of the lungs for nitric oxide before and 3 months after CF-LVAD implantation. After CF-LVAD, pulmonary function was not significantly changed (p >0.05). For lung diffusing capacity, alveolar volume (VA) was not changed (p = 0.47), but DLCO was significantly reduced (p = 0.04). After correcting for VA, DLCO/VA showed a trend toward reduction (p = 0.08). For the alveolar-capillary component, capillary blood volume (Vc) was significantly reduced (p = 0.04), and alveolar-capillary membrane conductance trended toward a reduction (p = 0.06). However, alveolar-capillary membrane conductance/Vc was not altered (p = 0.92). In conclusion, soon after CF-LVAD implantation, Vc is reduced likely because of pulmonary capillary derecruitment, which contributes to the decrease in lung diffusing capacity.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors have no conflicts of interest to declare.

Comment in

Publication types

LinkOut - more resources