Comparative Study
. 1986 Apr;10(1):15-22.
doi: 10.3109/03093648609103074.

Below-knee amputation: a comparison of the effect of the SACH foot and single axis foot on electromyographic patterns during locomotion

Comparative Study

Below-knee amputation: a comparison of the effect of the SACH foot and single axis foot on electromyographic patterns during locomotion

E G Culham et al. Prosthet Orthot Int. 1986 Apr.

Abstract

The purpose of this investigation was to measure the effect of two terminal prosthetic components, the SACH foot and the single axis foot, on the locomotion patterns of unilateral below-knee amputees. The ten subjects who participated in the study were evaluated on two occasions, once following prescription of a PTB prosthesis and one terminal device and once following its replacement with the second device. The two devices were allocated alternately at the time of prosthetic prescription to ensure that five of the subjects used the SACH foot initially and five used the single axis foot. The electromyographic activity of the vastus lateralis and medial hamstrings was recorded bilaterally during gait using Beckman surface electrodes. The EMG signals were full wave rectified and low pass filtered to obtain the linear envelope. Pressure sensitive foot-switches were used to correlate the EMG signals with components of the gait cycle. The pattern of quadriceps and hamstring muscle activity of the contralateral limb was similar to that reported for normal individuals and was unaffected by changing the terminal device on the prosthetic limb. The pattern of quadriceps and hamstring activity of the prosthetic limb differed from that of the contralateral limb and was influenced by the change in terminal device. With both devices the muscles were active for a greater percentage of the stance phase when compared to the contralateral limb. With the SACH foot attachment there appeared to be more contraction of the quadriceps and hamstrings during the mid stance phase of gait.

PubMed Disclaimer