Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
- PMID: 37263477
- DOI: 10.1016/j.jse.2023.04.020
Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
Abstract
Background: The purpose of this study is to report the clinical and radiologic outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D-printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up.
Methods: Following ethical approval, patients were identified and invited to participate. Inclusion criteria were (1) severe glenoid bone loss necessitating the need for custom implants and (2) patients with definitive glenoid and humeral components implanted more than 2 years prior. Included patients underwent clinical assessment using the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and the quick Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH). Radiographic assessment included anteroposterior and axial projections. Patients were invited to attend a computed tomography (CT) scan to confirm osseointegration. Statistical analysis used descriptive statistics (mean and standard deviation [SD]) and paired t test for parametric data.
Results: Eleven patients declined to participate. Five patients were deceased prior to study commencement, leaving 42 remaining patients in this analysis. Three patients had revision surgery before the 2-year follow-up; of these, 2 retained their custom glenoid components. Mean follow-up was 31.6 months from surgery (range 24-52 months). All 4 scores improved: OSS from a mean 15 (SD 8.4) to 36 (SD 12) (P < .001), Constant-Murley score from a mean 15 (SD 11.2) to 52 (SD 20.1) (P < .001), QuickDASH from a mean 70 (SD 21) to 31 (SD 24.8) (P = .004), and the ASES score from a mean 22 (SD 17.8) to 71 (SD 23.3) (P = .007). Radiologic evaluation demonstrated good osseointegration in all but 1 included patient.
Conclusion: The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex cohort. Large complex glenoid bone defects can be managed successfully with custom 3D-printed glenoid components.
Keywords: 3D-printed; Custom; arthroplasty; complex; replacement; revision; shoulder.
Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Early results of reverse total shoulder arthroplasty using a patient-matched glenoid implant for severe glenoid bone deficiency.J Shoulder Elbow Surg. 2020 Jul;29(7S):S139-S148. doi: 10.1016/j.jse.2020.04.024. J Shoulder Elbow Surg. 2020. PMID: 32643608
-
Short-term outcomes of reverse shoulder arthroplasty using a custom baseplate for severe glenoid deficiency.J Shoulder Elbow Surg. 2021 May;30(5):1060-1067. doi: 10.1016/j.jse.2020.08.002. Epub 2020 Aug 24. J Shoulder Elbow Surg. 2021. PMID: 32853790
-
Glenoid structural bone grafting in reverse total shoulder arthroplasty: clinical and radiographic outcomes.J Shoulder Elbow Surg. 2025 Feb;34(2):e103-e111. doi: 10.1016/j.jse.2024.05.008. Epub 2024 Jun 27. J Shoulder Elbow Surg. 2025. PMID: 38944375
-
Maximizing Implant Stability in the Face of Glenoid Bone Stock Deficiency.Orthop Clin North Am. 2024 Jan;55(1):101-111. doi: 10.1016/j.ocl.2023.05.011. Epub 2023 Jul 11. Orthop Clin North Am. 2024. PMID: 37980095 Review.
-
[Humeral and glenoid bone loss in shoulder arthroplasty : Classification and treatment principles].Orthopade. 2017 Dec;46(12):1008-1014. doi: 10.1007/s00132-017-3484-5. Orthopade. 2017. PMID: 29063145 Review. German.
Cited by
-
Management of Glenoid Bone Loss in Primary Reverse Total Shoulder Arthroplasty: A Critical Analysis Review.JB JS Open Access. 2025 Aug 7;10(3):e25.00131. doi: 10.2106/JBJS.OA.25.00131. eCollection 2025 Jul-Sep. JB JS Open Access. 2025. PMID: 40777213 Free PMC article. Review.
-
Current concepts in patient specific implants for reverse shoulder arthroplasty.JSES Int. 2025 Jan 8;9(3):771-778. doi: 10.1016/j.jseint.2024.12.007. eCollection 2025 May. JSES Int. 2025. PMID: 40486809 Free PMC article. Review.
-
Current trends in shoulder arthroplasty - Are the trends backed by evidence?J Clin Orthop Trauma. 2024 Dec 27;62:102897. doi: 10.1016/j.jcot.2024.102897. eCollection 2025 Mar. J Clin Orthop Trauma. 2024. PMID: 39872122
-
Custom Glenoid Baseplate to Address Massive Glenoid Bone Loss in Reverse Total Shoulder Arthroplasty.Video J Sports Med. 2024 Oct 10;4(5):26350254241259737. doi: 10.1177/26350254241259737. eCollection 2024 Sep-Oct. Video J Sports Med. 2024. PMID: 40309252 Free PMC article.
-
Patient-specific instrumentation technology enhances clinical outcomes in total elbow arthroplasty.BMC Surg. 2025 Apr 4;25(1):132. doi: 10.1186/s12893-025-02864-2. BMC Surg. 2025. PMID: 40186165 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources