Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul:177:107958.
doi: 10.1016/j.envint.2023.107958. Epub 2023 May 13.

A simple method for direct mercury analysis in dried blood spots (DBS) samples for human biomonitoring studies

Affiliations
Free article

A simple method for direct mercury analysis in dried blood spots (DBS) samples for human biomonitoring studies

Juana María González-Rubio et al. Environ Int. 2023 Jul.
Free article

Abstract

Human exposure to mercury can have serious health effects, especially in vulnerable groups such as children and fetuses. The use of dried blood spot (DBS) samples to collect capillary blood greatly facilitates sample collection and fieldwork, being a less invasive alternative to blood collection by venipuncture, needing a small volume of sample, and does not require specialized medical staff. Moreover, DBS sampling reduces logistical and financial barriers related to transport and storage of blood samples. We propose here a novel method to analyze total mercury in DBS samples in a Direct Mercury Analyzer (DMA) that allow the control of the volume of the DBS samples. This method has shown good results in terms of precision (<6% error), accuracy (<10% coefficient of variation) and recovery (75-106%). The applicability of the method in human biomonitoring (HBM) was demonstrated in a pilot study involving 41 adults aged 18-65. Mercury concentrations of DBS samples from capillary blood collected by finger prick (real DBS samples) were determined in the DMA and compared with those determined in whole blood (venous blood) by ICP-MS, the method usually used in HBM. The sampling procedure was also validated by comparison of real DBS samples and DBS generated artificially in the laboratory by depositing venous samples in cellulose cards (laboratory DBS). There were no statistically significant differences in the results obtained using both methodologies (DMA: Geometric Mean (confidence interval 95%) = 3.87 (3.12-4.79) µg/L; ICP-MS: Geometric Mean (confidence interval 95%) = 3.46 (2.80-4.27) µg/L). The proposed method is an excellent alternative to be applied in clinical settings as screening methodology for assessing mercury exposure in vulnerable groups, such us pregnant woman, babies and children.

Keywords: Direct Mercury Analyser (DMA); Dried Blood Spot (DBS); HBM4EU; Human Biomonitoring; Mercury; Microsampling; Non-invasive.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types

LinkOut - more resources