Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Apr;21(4):609-616.
doi: 10.1016/j.jacr.2023.04.010. Epub 2023 Jun 9.

Development and Operationalization of an Automated Workflow for Correlation of Knee MRI and Arthroscopy Findings

Affiliations

Development and Operationalization of an Automated Workflow for Correlation of Knee MRI and Arthroscopy Findings

Faysal Altahawi et al. J Am Coll Radiol. 2024 Apr.

Abstract

Objective: In this study, we sought to establish and evaluate an automated workflow to prospectively capture and correlate knee MRI findings with surgical findings in a large medical center.

Methods: This retrospective analysis included data from patients who had undergone knee MRI followed by arthroscopic knee surgery within 6 months during a 2-year period (2019-2020). Discrete data were automatically extracted from a structured knee MRI report template implementing pick lists. Operative findings were recorded discretely by surgeons using a custom-built web-based telephone application. MRI findings were classified as true-positive, true-negative, false-positive, or false-negative for medial meniscus (MM), lateral meniscus (LM), and anterior cruciate ligament (ACL) tears, with arthroscopy used as the reference standard. An automated dashboard displaying up-to-date concordance and individual and group accuracy was enabled for each radiologist. Manual correlation between MRI and operative reports was performed on a random sample of 10% of cases for comparison with automatically derived values.

Results: Data from 3,187 patients (1,669 male; mean age, 47 years) were analyzed. Automatic correlation was available for 60% of cases, with an overall MRI diagnostic accuracy of 93% (MM, 92%; LM, 89%; ACL, 98%). In cases reviewed manually, the number of cases that could be correlated with surgery was higher (84%). Concordance between automated and manual review was 99% when both were available (MM, 98%; LM, 100%; ACL, 99%).

Conclusion: This automated system was able to accurately and continuously assess correlation between imaging and operative findings for a large number of MRI examinations.

Keywords: Automation; dashboard; database; outcomes; rad-path.