Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Aug 10:811:137351.
doi: 10.1016/j.neulet.2023.137351. Epub 2023 Jun 14.

Comparison between conventional and neuronavigated strategies to assess corticospinal responsiveness in unfatigued and fatigued knee-extensor muscles

Affiliations
Free article

Comparison between conventional and neuronavigated strategies to assess corticospinal responsiveness in unfatigued and fatigued knee-extensor muscles

C Barbi et al. Neurosci Lett. .
Free article

Abstract

In studying neuromuscular fatigability, researchers commonly use functional criteria to position and hold the transcranial magnetic stimulation (TMS) coil during testing sessions. This could influence the magnitude of corticospinal excitability and inhibition responses due to imprecise and unsteady positions of the coil. To reduce coil position and orientation variability, neuronavigated TMS (nTMS) could be used. We evaluated the accuracy of nTMS and a standardized function-guided procedure for maintaining TMS coil position both in unfatigued and fatigued knee extensors. Eighteen participants (10F/8M) volunteered in two identical and randomized sessions. Maximal and submaximal neuromuscular evaluations were performed with TMS three times before (PRE_1) and three times after (PRE_2) a 2 min resting session and one time immediately after (POST) a 2-min sustained maximal voluntary isometric contraction (MVIC). The located "hotspot" [the location that evoked the largest motor-evoked potential (MEP) responses in the rectus femoris] was maintained either with or without nTMS. MEP, silent period (SP) and the distance between the "hotspot" and the actual coil position were recorded. A time × contraction intensity × testing session × muscle interaction was not observed for MEP, SP, and distance. Bland-Altman plots presented adequate agreements for MEP and SP. Spatial accuracy of TMS coil position over the motor cortex did not influence corticospinal excitability and inhibition in unfatigued and fatigued knee extensors. The variability in MEP and SP responses may be due to spontaneous fluctuations in corticospinal excitability and inhibition, and it is not altered by the spatial stability of the stimulation point.

Keywords: Corticospinal excitability; Corticospinal inhibition; Neuromuscular fatigability; Neuronavigator; Transcranial magnetic stimulation.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Similar articles

Publication types

LinkOut - more resources