Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jun 15;190(7):261.
doi: 10.1007/s00604-023-05839-3.

A molecularly imprinted electrochemical sensor with dual functional monomers for selective determination of gatifloxacin

Affiliations

A molecularly imprinted electrochemical sensor with dual functional monomers for selective determination of gatifloxacin

Yan Huang et al. Mikrochim Acta. .

Abstract

A molecularly imprinted electrochemical sensor was designed for the selective determination of gatifloxacin (GTX) based on dual functional monomers. Multi-walled carbon nanotube (MWCNT) enhanced the current intensity and zeolitic imidazolate framework 8 (ZIF8) provided a large surface area to produce more imprinted cavities. In the electropolymerization of molecularly imprinted polymer (MIP), p-aminobenzoic acid (p-ABA) and nicotinamide (NA) were used as dual functional monomers, and GTX was the template molecule. Taking [Fe(CN)6]3-/4- as an electrochemical probe, an oxidation peak on the glassy carbon electrode was located at about 0.16 V (vs. saturated calomel electrode). Due to the diverse interactions among p-ABA, NA, and GTX, the MIP-dual sensor exhibited higher specificity towards GTX than MIP-p-ABA and MIP-NA sensors. The sensor had a wide linear range from 1.00 × 10-14 to 1.00 × 10-7 M with a low detection limit of 2.61 × 10-15 M. Satisfactory recovery between 96.5 and 105% with relative standard deviation from 2.4 to 3.7% in real water samples evidenced the potential of the method in antibiotic contaminant determination.

Keywords: Differential pulse voltammetry; Dual functional monomers; Electrochemical sensor; Gatifloxacin; Molecularly imprinted polymer.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Jiang Z, Li G, Zhang M (2016) Electrochemical sensor based on electro-polymerization of β-cyclodextrin and reduced-graphene oxide on glassy carbon electrode for determination of gatifloxacin. Sens Actuators B Chem 228:59–65. https://doi.org/10.1016/j.snb.2016.01.013 - DOI
    1. Chen A, Li R, Zhong Y, Deng Q, Yin X, Li H, Kong L, Yang R (2022) A novel chiral fluorescence probe based on carbon dots-copper(II) system for ratio fluorescence detection of gatifloxacin. Sens. Actuators B Chem 359:131602. https://doi.org/10.1016/j.snb.2022.131602 - DOI
    1. Huang F, Chen L, Zhang C, Liu F, Li H (2022) Prioritization of antibiotic contaminants in China based on decennial national screening data and their persistence, bioaccumulation and toxicity. Sci. Total Environ 806:150636. https://doi.org/10.1016/j.scitotenv.2021.150636 - DOI - PubMed
    1. Jia A, Wan Y, Xiao Y, Hu J (2012) Occurrence and fate of quinolone and fluoroquinolone antibiotics in a municipal sewage treatment plant. Water Res 46:387–394. https://doi.org/10.1016/j.watres.2011.10.055 - DOI - PubMed
    1. Domingos LC, Moreira MV, Keller KM, Viana FA, Melo MM, Soto-Blanco B (2017) Simultaneous quantification of gatifloxacin, moxifloxacin, and besifloxacin concentrations in cornea and aqueous humor by LC-QTOF/MS after topical ocular dosing. J Pharmacol Toxicol Methods 83:87–93. https://doi.org/10.1016/j.vascn.2016.09.006 - DOI - PubMed

Publication types