Comparative analysis of visual outcomes with 2 enhanced monofocal intraocular lenses
- PMID: 37322813
- DOI: 10.1097/j.jcrs.0000000000001239
Comparative analysis of visual outcomes with 2 enhanced monofocal intraocular lenses
Abstract
Purpose: To compare the visual performance, spectacle independence, and subjective visual quality of 2 enhanced monofocal intraocular lenses (IOLs): Eyhance ICB00 and ZOE Primus-HD.
Setting: Ophthalmology Department, San Raffaele Scientific Institute, Milan, Italy.
Design: Prospective case series.
Methods: Patients without ocular comorbidities and corneal astigmatism <0.75 diopters (D) undergoing cataract surgery with bilateral implantation of enhanced monofocal Eyhance and ZOE were included. 6 months postoperatively, the following parameters were analyzed: subjective and objective refraction; monocular and binocular corrected (4 m) and uncorrected (UDVA) distance visual acuities; corrected distance, intermediate (66 cm), and near (40 cm) visual acuities, as well as uncorrected intermediate (UIVA) and uncorrected near (UNVA) visual acuities; photopic contrast sensitivity; binocular defocus curve; halo and glare perception; and spectacle independence.
Results: 100 eyes of 50 patients were evaluated (25 patients per IOL group). The 2 IOLs showed superimposable visual performances, without significant differences in terms of refractive and visual outcomes, defocus curves, contrast sensitivity, scores of vision quality, and spectacle independence. Of note, monocular and binocular UDVA was excellent in both groups. The 2 IOL models achieved satisfactory binocular UIVA, with more than 70% of patients reaching a binocular UIVA of ≤0.1 logMAR. Up to 84% of patients eventually declared to feel comfortable frequently while staying at intermediate distance.
Conclusions: The general visual outcome of the Eyhance ICB00 and the ZOE Primus-HD enhanced monofocal IOLs is similar, with special reference to the satisfactory spectacle independence for intermediate distance.
Copyright © 2023 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
References
-
- Häring G, Dick HB, Krummenauer F, Weissmantel U, Kröncke W. Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses: results of a multicenter questionnaire. J Cataract Refract Surg 2001;27:245–249
-
- Rosen E, Alió JL, Dick HB, Dell S, Slade S. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: metaanalysis of peer-reviewed publications. J Cataract Refract Surg 2016;42:310–328
-
- Alió JL, Plaza-Puche AB, Piñero DP, Amparo F, Rodríguez-Prats JL, Ayala MJ. Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal model. J Cataract Refract Surg 2011;37:638–648
-
- Shen Z, Lin Y, Zhu Y, Liu X, Yan J, Yao K. Clinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis. Sci Rep 2017;7:45337
-
- Gigon E, Bouthour W, Panos GD, Pajic B, Massa H. Real world outcomes of the new Tecnis Eyhance IOL. Eur J Ophthalmol 2023;33:1390–1397
MeSH terms
LinkOut - more resources
Full Text Sources
