Observational Study
. 2023 Oct 1;51(10):e201-e205.
doi: 10.1097/CCM.0000000000005964. Epub 2023 Jun 16.

Reliability of Respiratory System Compliance Calculation During Assisted Mechanical Ventilation: A Retrospective Study

Affiliations
Observational Study

Reliability of Respiratory System Compliance Calculation During Assisted Mechanical Ventilation: A Retrospective Study

Luca Bastia et al. Crit Care Med. .

Abstract

Objectives: To compare respiratory system compliance (C rs ) calculation during controlled mechanical ventilation (MV) and, subsequently, during assisted MV.

Design: This is a single-center, retrospective, observational study.

Setting: This study was conducted on patients admitted to Neuro-ICU of Niguarda Hospital (tertiary referral hospital).

Patients: We analyzed every patient greater than or equal to 18 years old having a C rs measurement in controlled and in assisted MV within 60 minutes. Plateau pressure (P plat ) was considered reliable if it was deemed visually stable for at least 2 seconds.

Interventions: Inspiratory pause was incorporated to detect P plat in controlled and assisted MV. Calculation of C rs and driving pressure were achieved.

Measurements and main results: A total of 101 patients were studied. An acceptable agreement was found (Bland-Altman plot bias -3.9, level of agreement upper 21.6, lower -29.6). C rs in assisted MV was 64.1 (52.6-79.3) and in controlled MV it was 61.2 (50-71.2) mL/cm H 2o ( p = 0.006). No statistical difference was found in C rs (assisted vs controlled MV) when peak pressure was lower than P plat nor when peak pressure was higher than P plat .

Conclusions: A P plat visually stable for at least 2 seconds leads to reliable C rs calculation during assisted MV.

PubMed Disclaimer

Conflict of interest statement

Dr. Fumagalli disclosed work for hire. The remaining authors have disclosed that they do not have any potential conflicts of interest.

Comment in

References

    1. Russotto V, Bellani G, Foti G: Respiratory mechanics in patients with acute respiratory distress syndrome. Ann Transl Med 2018; 6:382
    1. Grasselli G, Brioni M, Zanella A: Monitoring respiratory mechanics during assisted ventilation. Curr Opin Crit Care 2020; 26:11–17
    1. Bellani G, Grassi A, Sosio S, et al.: Plateau and driving pressure in the presence of spontaneous breathing. Intensive Care Med 2019; 45:97–98
    1. Bianchi I, Grassi A, Pham T, et al.: Reliability of plateau pressure during patient-triggered assisted ventilation. Analysis of a multicentre database [published correction appears in J Crit Care. 2022 Apr 1;:154030]. J Crit Care 2022; 68:96–103
    1. Rezoagli E, Bastia L, Grassi A, et al.: Paradoxical effect of chest wall compression on respiratory system compliance: A multicenter case series of patients with ARDS, with multimodal assessment. Chest 2021; 160:1335–1339

Publication types