Associations of flow disruptions with patient, staff, and process outcomes: a prospective observational study of robotic-assisted radical prostatectomies
- PMID: 37336845
- PMCID: PMC10462499
- DOI: 10.1007/s00464-023-10162-2
Associations of flow disruptions with patient, staff, and process outcomes: a prospective observational study of robotic-assisted radical prostatectomies
Abstract
Background: Technological advancements in the operating room (OR) have sparked new challenges for surgical workflow, OR professionals, and patient safety. Disruptive events are frequent across all surgical specialties, but little is known about their effects on patient outcomes and the influence of systemic factors. The aim was to explore the associations of intraoperative flow disruptions (FDs) with patient outcomes, staff workload, and surgery duration.
Methods: Prospective, single-center, and multi-source study comprising direct and standardized OR observations of urologic surgical procedures, clinical patient outcomes, and staff- and patient-reported outcome data (PROMs; 3-month follow-up). All data were recorded between 01/2020 and 10/2021. FDs were assessed using standardized procedure observations. Linear and logistic regression analyses including multiple system factors were used to explore the effects of FDs on surgical outcomes.
Results: 61 robotic-assisted radical prostatectomy procedures were captured (with 61 patients and 243 staff reports). High rates of FDs were observed; however, our analyses did not show significant relationships with patient complication rates. Equipment- and patient-related FDs were associated with increased staff workload. No association was found between higher rates of FDs and procedure duration.
Conclusions: FDs were not related to inferior patient outcomes. Our findings may inform future OR investigations that scrutinize the complex interplay of human, team, process, and technological components that mitigate the effects of FDs during surgery.
Trial registration: ClinicalTrials.gov NCT04226391.
Keywords: Flow disruptions; Patient safety; Prostate cancer; Robotic surgery; Teamwork.
© 2023. The Author(s).
Conflict of interest statement
Mrs. Amelie Koch, Dr. Caroline Quartucci, Prof. Dr. Alexander Buchner, Prof. Dr. Boris Schlenker, Prof. Dr. Armin Becker, Prof. Dr. Ken Catchpole, and Prof. Dr. Matthias Weigl have no conflicts of interest to disclose.
Figures
Similar articles
-
Effects of Flow Disruptions on Mental Workload and Surgical Performance in Robotic-Assisted Surgery.World J Surg. 2018 Nov;42(11):3599-3607. doi: 10.1007/s00268-018-4689-4. World J Surg. 2018. PMID: 29845381
-
Barriers to efficiency in robotic surgery: the resident effect.J Surg Res. 2016 Oct;205(2):296-304. doi: 10.1016/j.jss.2016.06.092. Epub 2016 Jul 4. J Surg Res. 2016. PMID: 27664876 Free PMC article.
-
Workflow disruptions in robot-assisted surgery.J Robot Surg. 2023 Dec;17(6):2663-2669. doi: 10.1007/s11701-023-01728-2. Epub 2023 Oct 10. J Robot Surg. 2023. PMID: 37815757 Free PMC article. Review.
-
Operating room team strategies to reduce flow disruptions in high-risk task episodes: resilience in robot-assisted surgery.Ergonomics. 2023 Aug;66(8):1118-1131. doi: 10.1080/00140139.2022.2136406. Epub 2022 Oct 26. Ergonomics. 2023. PMID: 36285451
-
Associations of workflow disruptions in the operating room with surgical outcomes: a systematic review and narrative synthesis.BMJ Qual Saf. 2020 Dec;29(12):1033-1045. doi: 10.1136/bmjqs-2019-010639. Epub 2020 May 23. BMJ Qual Saf. 2020. PMID: 32447319
Cited by
-
Noise in the operating room coincides with surgical difficulty.BJS Open. 2024 Sep 3;8(5):zrae098. doi: 10.1093/bjsopen/zrae098. BJS Open. 2024. PMID: 39413049 Free PMC article.
-
Intraoperative workload of the surgeon in robot-assisted radical prostatectomy: a systematic review.J Robot Surg. 2024 Jul 22;18(1):289. doi: 10.1007/s11701-024-02049-8. J Robot Surg. 2024. PMID: 39039389
References
Publication types
MeSH terms
Associated data
Grants and funding
LinkOut - more resources
Full Text Sources
Medical