Influence of abutment macro- and micro-geometry on morphologic and morphometric features of peri-implant connective tissue
- PMID: 37345230
- DOI: 10.1111/clr.14118
Influence of abutment macro- and micro-geometry on morphologic and morphometric features of peri-implant connective tissue
Abstract
Objectives: The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics.
Materials and methods: Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-μCT).
Results: Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-μCT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-μCT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups.
Conclusions: Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.
Keywords: collagen bundles; convergent abutment; divergent abutment; optical microscopy; peri-implant soft tissues; synchrotron imaging; ultrathin threaded surfaces.
© 2023 The Authors. Clinical Oral Implants Research published by John Wiley & Sons Ltd.
References
-
- Abrahamsson, I., Berglundh, T., Wennström, J., & Lindhe, J. (1996). The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog. Clinical Oral Implants Research, 7, 212-219.
-
- Belloni, A., Furlani, M., Greco, S., Notarstefano, V., Pro, C., Randazzo, B., Pellegrino, P., Zannotti, A., Carpini, G. D., Ciavattini, A., Di Lillo, F., Giorgini, E., Giuliani, A., Cinti, S., & Ciarmela, P. (2022). Uterine leiomyoma as useful model to unveil morphometric and macromolecular collagen state and impairment in fibrotic diseases: An ex-vivo human study. Biochimica et Biophysica Acta - Molecular Basis of Disease, 1868(12), 166494.
-
- Berglundh, T., Abrahamsson, I., Welander, M., Lang, N. P., & Lindhe, J. (2007). Morphogenesis of the peri-implant mucosa: An experimental study in dogs. Clinical Oral Implants Research, 18(1), 1-8.
-
- Berglundh, T., Jepsen, S., Stadlinger, B., & Terheyden, H. (2019). Peri-implantitis and its prevention. Clinical Oral Implants Research, 30, 150-155.
-
- Berglundh, T., & Lindhe, J. (1996). Dimension of the periimplant mucosa. Biological width revisited. Journal of Clinical Periodontology, 23, 971-973.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources