When dysplasia deceives instrumental results: Pseudo monocytosis on the sysmex XN haematological analyser and DI-60 digital morphology system: Cases report and literature review
- PMID: 37350511
- DOI: 10.1111/ijlh.14125
When dysplasia deceives instrumental results: Pseudo monocytosis on the sysmex XN haematological analyser and DI-60 digital morphology system: Cases report and literature review
Keywords: Macropolycytes; Sysmex XN analyser; digital morphology; granulocyte dysplasia; monocytosis.
Similar articles
-
Performance of the XN-2000 WPC channel-flagging to differentiate reactive and neoplastic leukocytosis.Clin Chem Lab Med. 2016 Sep 1;54(9):1503-10. doi: 10.1515/cclm-2015-1105. Clin Chem Lab Med. 2016. PMID: 26910746
-
Performance of automated digital cell imaging analyzer Sysmex DI-60.Clin Chem Lab Med. 2017 Nov 27;56(1):94-102. doi: 10.1515/cclm-2017-0132. Clin Chem Lab Med. 2017. PMID: 28672770
-
Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts.PLoS One. 2023 Jul 27;18(7):e0288551. doi: 10.1371/journal.pone.0288551. eCollection 2023. PLoS One. 2023. PMID: 37498851 Free PMC article.
-
Cytopenia, dysplasia, and monocytosis: a precursor to chronic myelomonocytic leukemia or a distinct subgroup? Case reports and review of literature.Clin Lymphoma Myeloma Leuk. 2011 Jun;11(3):293-7. doi: 10.1016/j.clml.2011.03.019. Epub 2011 Apr 20. Clin Lymphoma Myeloma Leuk. 2011. PMID: 21658659 Review.
-
Pseudo-erythroblastosis on Sysmex XN hematology analyzers: a clue to Candida sepsis. Case report and literature review.Clin Chem Lab Med. 2022 Jun 23;60(9):e210-e212. doi: 10.1515/cclm-2022-0486. Print 2022 Aug 26. Clin Chem Lab Med. 2022. PMID: 35730140 Review. No abstract available.
Cited by
-
Real-World Application of Digital Morphology Analyzers: Practical Issues and Challenges in Clinical Laboratories.Diagnostics (Basel). 2025 Mar 10;15(6):677. doi: 10.3390/diagnostics15060677. Diagnostics (Basel). 2025. PMID: 40150020 Free PMC article. Review.
References
REFERENCES
-
- Arber DA, Orazi A, Hasserjian RP, et al. International Consensus Classification of Myeloid Neoplasms and Acute Leukemias: integrating morphologic, clinical, and genomic data. Blood. 2022;140:1200-1228.
-
- Lesesve JF, Thomas B, Broséus J, Bain BJ. Macropolycytes: severe stress time for neutrophils. Morphologie. 2020;104:214-216.
-
- Bain BJ. Dysplastic macropolycytes in myelodysplasia-related acute myeloid leukaemia. Am J Hematol. 2011;86:776.
-
- Kim HN, Hur M, Kim H, Kim SW, Moon HW, Yun YM. Performance of automated digital cell imaging analyser Sysmex DI-60. Clin Chem Lab Med. 2018;56:94-102.
-
- Briggs C, Longair I, Kumar P, Singh D, Machin SJ. Performance evaluation of the Sysmex haematology XN modular system. J Clin Pathol. 2012;65:1024-1030.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources