. 2024 Jan;40(1):136-145.
doi: 10.1016/j.arthro.2023.06.021. Epub 2023 Jun 23.

Tape-Reinforced Graft Suturing and Retensioning of Adjustable-Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study

Affiliations

Tape-Reinforced Graft Suturing and Retensioning of Adjustable-Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study

Joseph D Lamplot et al. Arthroscopy. 2024 Jan.

Abstract

Purpose: To investigate the biomechanical effects of tape-reinforced graft suturing and graft retensioning for all-soft tissue quadriceps tendon (ASTQT) anterior cruciate ligament reconstruction (ACLR) in a full-construct human cadaveric model.

Methods: Harvested cadaveric ASTQT grafts were assigned to either (1) double-suspensory adjustable-loop cortical button device (ALD) fixation in which both graft ends were fixed with a suspensory fixation device with (n = 5) or without (n = 5) tape-reinforced suturing or (2) single-suspensory distal tendon fixation in which only the patellar end was fixed with an ALD (n = 5) or fixed-loop cortical button device (FLD) (n = 5). All specimens were prepared using a No. 2 whipstitch technique, and tape-reinforced specimens had an integrated braided tape implant. Graft preparation time was recorded for double-suspensory constructs. Samples were tested on an electromechanical testing machine using a previously published protocol simulating rehabilitative kinematics and loading.

Results: Tape-reinforced graft suturing resulted in greater graft load retention after cycling (11.9% difference, P = .021), less total elongation (mean [95% confidence interval (CI)], 5.57 mm [3.50-7.65 mm] vs 32.14 mm [25.38-38.90 mm]; P < .001), greater ultimate failure stiffness (mean [95% CI], 171.9 N/mm [158.8-185.0 N/mm] vs 119.4 N/mm [108.7-130.0 N/mm]; P < .001), and less graft preparation time (36.4% difference, P < .001) when compared with unreinforced specimens. Retensioned ALD constructs had less cyclic elongation compared with FLD constructs (mean total elongation [95% CI], 7.04 mm [5.47-8.61 mm] vs 12.96 mm [8.67-17.26 mm]; P = .004).

Conclusions: Tape-reinforced graft suturing improves time-zero ASTQT ACLR construct biomechanics in a cadaveric model with 83% less total elongation, 44% greater stiffness, and reduced preparation time compared with a whipstitched graft without tape reinforcement. ALD fixation improves construct mechanics when compared with FLD fixation as evidenced by 46% less total elongation.

Clinical relevance: Tape-reinforced implants and graft retensioning using ALDs improve time-zero ACLR graft construct biomechanics in a time-zero biomechanical model. Clinical studies will be necessary to determine whether these implants improve clinical outcomes including knee laxity and the incidence of graft rupture.